Cingo Residential Home Inspection

123 Any St

Atlanta, GA 30120

Year Built : 1994 Sq.Footage : 2391 Occupied : Vacant, Unfurnished Utilities : Water, Gas, Electric Weather : Clear
  • Summary

    289 Items Inspected

    DEFECT #0 OF 0

    Attic

    Insulation / Ventilation: Attic

    DEFICIENCY 2.2
    Attic Hatch Needs Cover

    Repair: The attic access cover is missing and should be installed to limit flow of air from the attic int...

    Garage

    Exterior: Garage

    DEFICIENCY 3.1
    Opener Inoperative

    Repair: The garage door opener appears to be inoperative. It should be repaired as necessary by a qualifi...

    Garage

    Exterior: Garage

    DEFICIENCY 3.2
    Impact Reverse Adjustment Needed

    Repair, Safety Issue: The garage door opener did not automatically reverse using standard testing procedu...

    Structural Components

    Structural: Foundation

    DEFICIENCY 4.1
    French Drains - Monitor

    Monitor: The ends of the french drains which should surround the perimeter footings (appear to be at the ...

    Roofing System

    Roofing: Shingles / Membrane

    DEFICIENCY 5.1
    General Repairs Needed

    Repair: General repairs to the roofing are needed, which should be performed by a qualified roofing contr...

    Roofing System

    Roofing: Flashings

    DEFICIENCY 5.2
    Older Flashing - Replace

    Repair: The flashing components as noted is older material and should be replaced altogether to avoid lea...

    Roofing System

    Roofing: Gutters / Downspouts

    DEFICIENCY 5.4
    Downspouts Discharge Near House

    Repair: All of the downspouts should be piped away from the foundation so that they discharge water at le...

    Exterior Components

    Exterior Veneer: Siding / Trim Eaves

    DEFICIENCY 6.1
    Hardboard Siding (Monitor)

    Monitor: Hardboard siding such as this has a limited life and is susceptible to weather damage. While it ...

    Exterior Components

    Exterior Veneer: Stucco

    DEFICIENCY 6.3
    Eifs Grade Contact

    Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and ...

    Exterior Components

    Exterior Veneer: Stucco

    DEFICIENCY 6.4
    Eifs Exposed Foam At Grade

    Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and ...

    Exterior Components

    Exterior: Windows / Doors

    DEFICIENCY 6.5
    Door Rot Noted

    Repair: The door frames show various degrees of rot/damage and needs repairs. Following repair of the dam...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.8
    Bolt Missing Washer and Nut

    Repair: One of the bolts attaching the deck ledger to the structure of the house was missing its washer a...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.9
    Deck Supported By Bay Or Overhang

    Repair, Safety Issue:  Decks should not be supported by bays or overhangs and in such cases, should be s...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.10
    Open Risers / Openings Between Treads >4"

    Repair, Safety Issue: Openings between stairs treads are not allowed to be greater than 4" as recommended...

    Electrical System

    Electrical: Panels

    DEFICIENCY 7.1
    Mismatched Breakers

    Monitor, Possible Repair: It appears that circuit breakers have been installed in the main electrical pan...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.3
    Damaged Outlet

    Repair, Safety Issue: Damaged outlets as noted should be replaced to prevent shocking hazards. The electr...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.4
    Reversed Polarity Outlet

    Repair, Safety Issue: Outlets having reversed polarity (hot and neutral wires reversed) as noted (s) shou...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.8
    GFCI Outlet Did Not Trip Properly

    Repair, Safety Issue: A ground fault circuit interrupter (GFCI) outlet as noted did not respond correctly...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.9
    GFCI Recommended All Locations

    Improve, Safety Issue: The installation of ground fault circuit interrupter (GFCI) outlets is recommended...

    Electrical System

    Electrical: Switches

    DEFICIENCY 7.11
    Switch Needed for Light in the Bonus Room

    Repair: A light switch for the bonus room could not be found at the time of the inspection. Have the elec...

    Electrical System

    Electrical: Lighting

    DEFICIENCY 7.12
    Damaged Light Fixture

    Repair: The damaged light fixture as noted should be repaired or replaced as needed for proper function.

    Electrical System

    Electrical: Smoke / CO Detectors

    DEFICIENCY 7.14
    Detector Missing

    Repair, Safety Issue: Missing smoke alarms as noted should be reinstalled and tested as needed for proper...

    Cooling System

    Cooling: Outdoor Condensing Unit

    DEFICIENCY 8.1
    Outdoor Unit Out Of Level

    Repair: The outdoor unit of the air conditioning system is out of level. This condition should be correct...

    Cooling System

    Cooling: Outdoor Condensing Unit

    DEFICIENCY 8.2
    Outdoor Unit Noisy

    Monitor, Possible Repair: The outdoor unit of the air conditioning system is excessively noisy, which cou...

    Heating System

    Heating: Furnace / Air Handler

    DEFICIENCY 9.1
    Servicing Needed (Dirty Air Filter)

    Repair, Safety Issue: The dirty air filter(s) as noted should be replaced. Dirty filters indicate the sys...

    Heating System

    Heating: Furnace / Air Handler

    DEFICIENCY 9.3
    Fan Shut-Off Switch Repair

    Repair, Safety Issue: The automatic shut-off switch for the blower fan at the furnace did not shut the sy...

    Heating System

    Heating: Gas Piping

    DEFICIENCY 9.5
    Flexible Gas Piping

    Repair, Safety Issue: The gas supply line serving the furnace is flexible piping which passes through the...

    Heating System

    Heating: Combustion / Exhaust

    DEFICIENCY 9.6
    Flue Clearance

    Repair, Safety Issue: There is insufficient clearance between the exhaust flue and combustible materials ...

    Heating System

    Heating: Ductwork

    DEFICIENCY 9.7
    Clean Ductwork (Older System)

    Improve, Safety Issue: Due to the age of the ductwork and dust noted in the system, recommend having all ...

    Plumbing System

    Plumbing: Water Heaters

    DEFICIENCY 10.2
    Older Water Heater

    Monitor, Future Repair: The water heater is an older unit that has lasted beyond its typical life span. I...

    Plumbing System

    Plumbing: Water Heaters

    DEFICIENCY 10.3
    Vent Pipe - Negative Slope

    Repair, Safety Issue: The slope on the water heater vent pipe does not appear to be sufficient for proper...

    Insulation / Ventilation

    Insulation / Ventilation: Windows and Doors

    DEFICIENCY 11.3
    Repair Door Weatherstripping

    Repair: The weatherstripping is damaged and should be repaired or replaced as needed to limit outside air...

    Interior Components

    Interior: Ceilings / Walls

    DEFICIENCY 12.1
    Previous Patching Noted

    Monitor: Previous damage was noted in the walls/ceilings, which has been repaired. Consult with seller co...

    Interior Components

    Interior: Flooring

    DEFICIENCY 12.2
    Toe Trip Hazard

    Repair, Safety Issue: The transition at the top of the steps at the carpet and flooring as noted poses...

    Interior Components

    Interior: Windows

    DEFICIENCY 12.3
    Bedroom Windows Painted Shut

    Repair, Safety Issue: A majority of the windows are painted or otherwise stuck shut. Present day safety s...

    Interior Components

    Interior: Windows

    DEFICIENCY 12.4
    Fogged Glass

    Repair: "Fogged" glass was noted, which should be replaced. This condition is typically caused by damaged...

    Interior Components

    Interior: Cabinetry

    DEFICIENCY 12.5
    Seal Interior Of Cabinets

    Repair: The inside panels of the cabinets as noted should be repaired and sealed to prevent the infiltrat...

    Interior Components

    Interior: Stairways

    DEFICIENCY 12.6
    Handrail Missing

    Repair, Safety Issue: Handrails are required when there are four or more steps. Add handrail for proper s...

    Appliances / Fireplaces

    Fireplaces

    DEFICIENCY 13.1
    Fireplace Servicing Needed?

    Possible Repair, Safety Issue: Since the chimney flue(s) are not entirely visible, we recommend that you ...

    Appliances / Fireplaces

    Fireplaces

    DEFICIENCY 13.2
    Gas Logs Turned Off

    Monitor: Check with the seller concerning the proper operation of the gas logs as the pilot was not lit a...

    Appliances / Fireplaces

    Appliances: Cooktop / Oven

    DEFICIENCY 13.3
    Anti-Tip Device Needed

    Repair, Safety Issue: There was no apparent anti-tip device installed for the oven/range unit, which shou...

    Appliances / Fireplaces

    Appliances: Disposal

    DEFICIENCY 13.4
    Disposal Inoperative?

    Monitor, Possible Repair: The waste disposal did not turn on with the switch nearby and is either inopera...

    Appliances / Fireplaces

    Appliances: Refrigerator / Ice Maker

    DEFICIENCY 13.5
    Damage Noted

    Repair: Several items were noted as damaged on the refrigerator: freezer exterior handle, interior door s...

    Appliances / Fireplaces

    Appliances: Dryer / Washing Machine

    DEFICIENCY 13.7
    Clean Dryer Vent

    Repair, Safety Issue: The clothes dryer exhaust vent pipe appears clogged with lint and should be cleaned...

    Appliances / Fireplaces

    Appliances: Microwave

    DEFICIENCY 13.10
    Microwave Light Inoperative

    Repair: The light did not operate when tested using standard controls. Replace bulb and test; consult a...

Report Remarks

Thank you for choosing Cingo to inspect your home. We completed a visual inspection of the property on the date noted above and have included deficiencies found under each category. Not all deficiencies will be present in the report summary; please read the entire report for the complete assessment of the home, paying particular attention to the items in the report summary. If at any time you have questions, feel free to contact your inspector or our office.

To review our Standards of Practice, view... https://ashiwebstorage.blob.core.windows.net/files/docs/standards_updated3-4-2015.pdf

Inspection Details Info

  • General : In AttendanceClient, Buyer Agent
  • General : OccupancyVacant, Unfurnished
  • General : Style Of HomeRanch, Multi-Level
  • General : UtilitiesWater, Gas, Electric
  • General : WeatherClear

Attic

Insulation / Ventilation: Attic

DEFICIENCY 2.1
Improve Attic Insulation

Improve: The attic insulation should be improved to R38, which is present day standard. The attic access panel (when installed) should be insulated with foam board and weather-stripped or otherwise covered to limit unconditioned air infiltration into finished areas.

Attic

Insulation / Ventilation: Attic

DEFICIENCY 2.2
Attic Hatch Needs Cover

Repair: The attic access cover is missing and should be installed to limit flow of air from the attic into the living areas. The cover should be insulated with foam board and weather-stripped to limit unconditioned air infiltration into finished areas. Otherwise an insulated cover could be placed over the opening. Make sure all side attic access doors are also insulated and weather-stripped.

Attic Info

  • General : Attic AccessAccessible via Scuttle Hole in Ceiling, Located: Upstairs Closet
  • General : Attic InsulationFiberglass, Estimated R Value: R25-R30 in Main Attic
  • General : Attic FlooringUn-Floored
Opener Inoperative
Opener Inoperative

Garage

Exterior: Garage

DEFICIENCY 3.1
Opener Inoperative

Repair: The garage door opener appears to be inoperative. It should be repaired as necessary by a qualified garage door company. The reversing mechanism should be checked for proper operation.

Garage

Exterior: Garage

DEFICIENCY 3.2
Impact Reverse Adjustment Needed

Repair, Safety Issue: The garage door opener did not automatically reverse using standard testing procedures as required by the National Safety Council (door must reverse upon hitting a 2x4 block of wood laid flat on the floor below the door). There is a risk of injury, particularly to children, and damage to vehicles under this condition. The opener and door should be serviced and adjusted as needed by a qualified garage door service company.

Garage

Exterior: Garage

DEFICIENCY 3.3
Electric Eyes - Wrong Height

Repair, Safety Issue: The electric eyes (safety beams) for the garage door opener(s) are not set at a proper height for safe operation (should be set at 4" - 6" from floor per manufacturer's recommendations). These should be adjusted as necessary for proper operation and safety.

Garage Info

  • General : Garage TypeAttached
  • General : Number Of BaysTwo Car
  • General : Overhead Garage DoorsMetal, Automatic Opener (electric eye reversing mechanism)

Structural Components

Structural: Foundation

DEFICIENCY 4.1
French Drains - Monitor

Monitor: The ends of the french drains which should surround the perimeter footings (appear to be at the location pictured). Monitoring these are important for insuring that the system is draining properly. Make sure they are not tied to an underground piping system for the downspouts. This condition could allow water to become trapped next to the foundation should the piping become clogged with debris.

Structural Components

Structural: Slabs

DEFICIENCY 4.2
Minor Cracks - Monitor

Monitor: Minor cracking was noted in the concrete slab. This type and pattern of cracking is usually the result of concrete shrinkage as it cures. Shrinkage cracks are very common and are not normally a concern.

Structural Components Info

  • General : FoundationSlab on Grade (Basement and Garage Slab), Concrete Block Walls
  • General : Columns/PiersSteel Columns
  • General : Floor StructureWood Joists - 2x10, Plywood Floor Decking, Not Totally Visible (due to finishes)
  • General : Wall StructureStud Size: 2x4, Above Components Assumed (not totally visible)
  • General : Ceiling StructureWood Joist - 2x8, Not Totally Visible
  • General : Roof StructureWood Rafters - 2x6, Plywood Sheathing
  • General : Crawlspace AccessN/A
To view additional Structural Components Photos, Click Here.

Roofing System

Roofing: Shingles / Membrane

DEFICIENCY 5.1
General Repairs Needed

Repair: General repairs to the roofing are needed, which should be performed by a qualified roofing contractor. Damaged or missing roofing shingles as noted should be replaced. All "eyebrows" (shingles that are lifted up by protruding nail heads) as noted should be repaired by lifting the shingles and re-driving the nails in the decking. All holes and exposed nail heads should be caulked and sealed. All roof penetrations should also be examined and sealed as necessary, especially as noted.

Roofing System

Roofing: Flashings

DEFICIENCY 5.2
Older Flashing - Replace

Repair: The flashing components as noted is older material and should be replaced altogether to avoid leaks.

Roofing System

Roofing: Flashings

DEFICIENCY 5.3
Kick-Out Flashing Needed (Siding)

Repair: No "kick-out" flashing was noted at the intersection of the gutters and siding as noted, which is needed to prevent moisture intrusion into the wall system. This should be installed at all required locations by a qualified contractor as needed for proper moisture protection (see illustration below for details).

Downspouts Discharge Near House
Downspouts Discharge Near House
Downspouts Discharge Near House
Downspouts Discharge Near House
Downspouts Discharge Near House

Roofing System

Roofing: Gutters / Downspouts

DEFICIENCY 5.4
Downspouts Discharge Near House

Repair: All of the downspouts should be piped away from the foundation so that they discharge water at least ten (10) feet from the house or into an underground drainage system to prevent moisture infiltration into the basement and settlement of the foundation. The drainage at the left front side appears to be contributing to the damage to the driveway. Recommend using smooth wall piping as opposed to the black ribbed piping, which is more prone to blockages. Storm water should be encouraged to flow away from the building at the point of discharge.

Roofing System Info

  • General : Roof TypeComposition Shingle Standard Weight
  • General : Roof FlashingsMetal, Vinyl (at plumbing stacks), Drip Edge Flashing
  • General : ChimneysMetal Flue / Siding Veneer
  • General : Gutters And DownspoutsAluminum, Gutter Helmets, Downspouts Discharge above Grade
  • General : SkylightsNone Located
  • General : Method Of InspectionViewed from Ladder at Eave
To view additional Roofing System Photos, Click Here.
Hardboard Siding (Monitor)
Hardboard Siding (Monitor)
Hardboard Siding (Monitor)

Exterior Components

Exterior Veneer: Siding / Trim Eaves

DEFICIENCY 6.1
Hardboard Siding (Monitor)

Monitor: Hardboard siding such as this has a limited life and is susceptible to weather damage. While it may be possible to prolong the life of this material, substantial re-siding may ultimately be necessary. In the meantime, the siding should be kept well caulked and painted to prevent moisture intrusion and damage.

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.2
Eifs Warning

Monitor, Possible Concern: EIFS (Exterior Insulation and Finish System - sometimes referred to as "Synthetic Stucco"), as noted on this structure, has had moisture problems in the past with poor installations. It is important that these systems are kept well caulked and sealed to prevent moisture from infiltrating the structure, which can cause damage. All windows, doors, chimneys and intersecting roofs should be properly flashed. Consider having the entire veneer inspected by a stucco repair contractor for repairs and improvements that may be needed.

Eifs Grade Contact
Eifs Grade Contact
Eifs Grade Contact

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.3
Eifs Grade Contact

Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and sealed at all times. The bottom edge of this veneer appears to be in contact with the soil, which can be a source of moisture and insect infiltration. All foam board should be cut back to provide at least 6" clearance with the soil and the exposed edges properly sealed. All joints with woodwork should be properly caulked. All windows, doors, chimneys and intersecting roofs should be properly flashed. Consult with a professional stucco contractor adept in repairing these systems.

Eifs Exposed Foam At Grade
Eifs Exposed Foam At Grade

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.4
Eifs Exposed Foam At Grade

Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and sealed at all times. The bottom edge of this veneer appears to have been cut back from the grade but the edge of the foam backing is exposed which can be a source of moisture and insect infiltration. All exposed edges of the foam should be properly sealed and all joints with woodwork properly caulked. Consult with a professional stucco contractor adept in repairing these systems.

Door Rot Noted
Door Rot Noted
Door Rot Noted

Exterior Components

Exterior: Windows / Doors

DEFICIENCY 6.5
Door Rot Noted

Repair: The door frames show various degrees of rot/damage and needs repairs. Following repair of the damaged areas (which should be combined with exterior painting) proper maintenance of the windows and doors and control of water from roof or surface runoff can avoid further damage.

Exterior Components

Exterior: Windows / Doors

DEFICIENCY 6.6
Adjust Exterior Door

Improve: Exterior doors should be adjusted to close and fit properly as noted for ease of operation and to limit outside air and moisture infiltration.

Exterior Components

Exterior: Decks

DEFICIENCY 6.7
Deck Repairs Needed

Repair, Safety Issue: Repairs are recommended at the rear wood deck for proper safety as listed below, which should be performed by a qualified framing contractor. The contractor should assess all components for proper performance and safety:

Exterior Components

Exterior: Decks

DEFICIENCY 6.8
Bolt Missing Washer and Nut

Repair: One of the bolts attaching the deck ledger to the structure of the house was missing its washer and nut. Repair and check all bolts.

Exterior Components

Exterior: Decks

DEFICIENCY 6.9
Deck Supported By Bay Or Overhang

Repair, Safety Issue:  Decks should not be supported by bays or overhangs and in such cases, should be self supported with columns.  The area of the deck at the location pictured is attached to and appears to be supported by the overhang and should instead be supported by separate columns installed on proper footings under the floor system.

Exterior Components

Exterior: Decks

DEFICIENCY 6.10
Open Risers / Openings Between Treads >4"

Repair, Safety Issue: Openings between stairs treads are not allowed to be greater than 4" as recommended for child safety.

Grade Contact With Wood Columns
Grade Contact With Wood Columns
Grade Contact With Wood Columns
Grade Contact With Wood Columns

Exterior Components

Exterior: Decks

DEFICIENCY 6.11
Grade Contact With Wood Columns

Repair: The grade is in contact with the base of the support wood posts for the deck, which can cause moisture and termite damage in the future. Recent studies have shown that even pressure treated wood can rot over time due to constant contact with the soil. Make sure the footings for the posts are in place and extend at least 2" above the ground to keep the bottoms of the posts dry and free from soil contact.

Exterior Components

Exterior: Decks

DEFICIENCY 6.12
Deck Paint / Stain Needed

Improve: The wood deck should be power-washed and then painted or stained to improve durability and protection against further weather damage.

Exterior Components

Exterior: Patios / Stoops / Steps

DEFICIENCY 6.13
Steps Settled

Possible Repair, Safety Issue: The steps at the rear have settled. Repairs or rebuilding altogether should be considered for improved safety. A landing is needed.

Handrail Needed (Improve)
Handrail Needed (Improve)

Exterior Components

Exterior: Patios / Stoops / Steps

DEFICIENCY 6.14
Handrail Needed (Improve)

Improve, Safety Issue: Recommend installing a handrail at the exterior steps at the location pictured for improved safety. Current safety standards recommend a handrail for steps of four (4) or more risers.

Exterior Components

Exterior: Patios / Stoops / Steps

DEFICIENCY 6.15
Patio Settled / Cracked

Monitor, Possible Repair: The patio pavers have settled and cracked and may need repair or replacement in the future.

Exterior Components

Exterior: Driveway / Sidewalks

DEFICIENCY 6.16
Driveway Settlement / Heaving

Repair: The driveway has heaved and cracked in some areas as noted and will need repair or replacement. Drainage improvements (see “Roofing” section) are needed to prevent additional damage. The pine tree at the end of the driveway should be evaluated by an arborist to determine of it is causing damage to the driveway.

Exterior Components

Exterior: Retaining Walls

DEFICIENCY 6.17
Retaining Wall Leaning

Monitor, Future Repair: The retaining wall is leaning noticeably and may need major repair or replacement in the near future.

Exterior Components

Exterior: Landscaping / Fencing

DEFICIENCY 6.19
Cut Back Overhanging Limbs

Improve: All overhanging limbs as noted should be cut back to prevent further damage to the roofing shingles and gutters and to prevent rodent infestations into the attic.

Exterior Components Info

  • General : Wall CoveringFiber Cement Siding, Hardboard Siding, EIFS (Exterior Insulation and Finishing System)
  • General : Eaves / Soffits / FasciasWood
  • General : Exterior DoorsWood, Metal
  • General : Window / Door Frames And TrimWood
  • General : Entry Driveways / Walkways / PatiosConcrete
  • General : Front Entry / PorchWood Handrailings
  • General : Other Porches / Decks / Steps And RailingsWood Deck, Wood Railings
  • General : Surface DrainageGraded Away From Building at Rear, Graded Away From Building at Left
  • General : Retaining WallsWood Landscaping Timbers
  • General : FencingNone
  • General : Number Of Exterior Doors4
  • General : Number Of Rooms With Windows With Grade Access3
To view additional Exterior Components Photos, Click Here.

Electrical System

Electrical: Panels

DEFICIENCY 7.1
Mismatched Breakers

Monitor, Possible Repair: It appears that circuit breakers have been installed in the main electrical panel that are of a type that do not match with the manufacturer of the panel. This condition can cause the breakers to be uneven and loose, which can lead to poor electrical connections. Have an electrician assess this condition and replace all mismatched breakers as necessary.

Electrical System

Electrical: Wiring / Boxes

DEFICIENCY 7.2
Open Junction Boxes

Repair: All open junction boxes as noted should be fitted with cover plates, in order to protect the wiring and to reduce the risks of potential fires that may be caused by poor connections.

Damaged Outlet
Damaged Outlet
Damaged Outlet

Electrical System

Electrical: Outlets

DEFICIENCY 7.3
Damaged Outlet

Repair, Safety Issue: Damaged outlets as noted should be replaced to prevent shocking hazards. The electrician should check all interior and exterior for damage and replace as needed. 

Reversed Polarity Outlet
Reversed Polarity Outlet
Reversed Polarity Outlet

Electrical System

Electrical: Outlets

DEFICIENCY 7.4
Reversed Polarity Outlet

Repair, Safety Issue: Outlets having reversed polarity (hot and neutral wires reversed) as noted (s) should be investigated and repaired as necessary. Wiring at the outlet or in the panel may need reconfiguration.  The electrician should check all outlets and switches for proper wiring.

Missing Cover Plates
Missing Cover Plates

Electrical System

Electrical: Outlets

DEFICIENCY 7.5
Missing Cover Plates

Repair, Safety Issue: Missing outlet and damaged cover plates as noted should be replaced as needed to avoid a shock hazard.

Electrical System

Electrical: Outlets

DEFICIENCY 7.6
4 Prong Outlet Needed At Dryer Improve

Improve: The dryer outlet does not meet current standards for grounding requirements (4-pronged outlets now required). Recommend having an electrician change this outlet to the newer 4-pronged outlet if a newer model dryer is used.

Electrical System

Electrical: Outlets

DEFICIENCY 7.7
Exterior Outlets Need Weatherproof Covers

Improve: Up to date and tighter weatherproof covers should be installed on the exterior outlets as noted to prevent moisture intrusion and damage to the wiring.

GFCI Outlet Did Not Trip Properly
GFCI Outlet Did Not Trip Properly

Electrical System

Electrical: Outlets

DEFICIENCY 7.8
GFCI Outlet Did Not Trip Properly

Repair, Safety Issue: A ground fault circuit interrupter (GFCI) outlet as noted did not respond correctly to testing with an outlet tester. The receptacle(s) and circuit(s) should be investigated and repaired by a licensed electrician as needed for proper protection. The electrician should check all GFCI outlets for proper operation and locations and make repairs as needed.

Electrical System

Electrical: Switches

DEFICIENCY 7.11
Switch Needed for Light in the Bonus Room

Repair: A light switch for the bonus room could not be found at the time of the inspection. Have the electrician install a switch to control the light or identify where the switch is located. 

Electrical System

Electrical: Lighting

DEFICIENCY 7.12
Damaged Light Fixture

Repair: The damaged light fixture as noted should be repaired or replaced as needed for proper function.

Electrical System

Electrical: Smoke / CO Detectors

DEFICIENCY 7.14
Detector Missing

Repair, Safety Issue: Missing smoke alarms as noted should be reinstalled and tested as needed for proper safety. At a minimum, smoke detectors should be installed outside each bedroom and at every level of the home.

ADDITIONAL INFO - CUSTOM 7.15

GFCI Reset Location

Monitor: The reset buttons for the GFCI outlets located in the bathrooms and exteriors, as applicable, are at the locations pictured.

Electrical System Info

  • General : Size Of Electrical Service120/240 Volt Main Service - Service Size: 150 Amps
  • General : Service DropUnderground
  • General : Electrical Service ConductorsAluminum - 2/0 AWG
  • General : Main Service Disconnect(s)Main Breaker Rating 150 Amps
  • General : Main Service Disconnect LocationMain Panel
  • General : Service GroundingGround Rod Connection
  • General : Overcurrent ProtectionBreaker Panel - Unknown Rating
  • General : Distribution Panel Location(s)Garage
  • General : Distribution Sub-Panel(s)125 Amp Breaker Panel(s), Located: Garage
  • General : Distribution WiringCopper, "Romex"
  • General : Switches And ReceptaclesGrounded and Ungrounded
  • General : Ground Fault Circuit Interrupters (GFCI)Bathrooms, Kitchen, Exterior (Partial), Garage
  • General : Arc Fault Circuit Interrupters (AFCI)None Found
  • General : Smoke DetectorsPresent
  • General : Security SystemYES
To view additional Electrical System Photos, Click Here.

Cooling System

Cooling: Outdoor Condensing Unit

DEFICIENCY 8.1
Outdoor Unit Out Of Level

Repair: The outdoor unit of the air conditioning system is out of level. This condition should be corrected to allow for proper operation of the fan motor and compressor.

Cooling System

Cooling: Outdoor Condensing Unit

DEFICIENCY 8.2
Outdoor Unit Noisy

Monitor, Possible Repair: The outdoor unit of the air conditioning system is excessively noisy, which could indicate bad bearings in the compressor or fan motor. This condition should be further investigated during servicing and repaired as needed.

ADDITIONAL INFO - CUSTOM 8.3

Data Tag (Condensing Unit)

Reference photo(s) of manufacturer data tag(s).

Cooling System Info

  • General : Cooling Equipment Energy SourceElectricity
  • General : Cooling System TypeAir Cooled Central Air
  • General : Number Of A/C SystemsOne
  • General : Central Air ManufacturerRHEEM
  • General : Distribution MethodsDuctwork
  • General : Outdoor Unit Location(s)Rear Yard
  • General : Tonnage Capacity4 Tons Total (1 ton serves ~600 SF)
  • General : Cooling Equipment Age (Typical Service Lifespan 8-12 Years)6
To view additional Cooling System Photos, Click Here.

Heating System

Heating: Furnace / Air Handler

DEFICIENCY 9.1
Servicing Needed (Dirty Air Filter)

Repair, Safety Issue: The dirty air filter(s) as noted should be replaced. Dirty filters indicate the systems may have not been serviced recently. The furnace(s) should be serviced and cleaned by a qualified HVAC service company before closing if this has not been done within the last six months according to manufacturers' recommendations. The heat exchangers should be checked for cracks, which can allow carbon monoxide poisoning to infiltrate the supply air. The gas venting system should be checked for proper drafting and safety. Check with the seller concerning all previous service records.

Heating System

Heating: Furnace / Air Handler

DEFICIENCY 9.2
Furnace Non-Op (Add To Std Service Comment)

Repair, Possible Concern: The furnace did not respond to the thermostat, which indicates repairs may be needed. A licensed heating and air conditioning service company should evaluate this condition and make repairs as necessary.

Heating System

Heating: Furnace / Air Handler

DEFICIENCY 9.3
Fan Shut-Off Switch Repair

Repair, Safety Issue: The automatic shut-off switch for the blower fan at the furnace did not shut the system off as is necessary to prevent combustion air from contaminating the air supply for the system. Proper operation of this safety device should be checked for all furnaces and repaired as needed by the HVAC technician.

Heating System

Heating: Furnace / Air Handler

DEFICIENCY 9.4
Label Furnace Shut-Off Switch

Improve: Recommend labeling the furnace shut-off switch(s) (switch closest to the furnace) to prevent someone from shutting off the furnace by accident.

Heating System

Heating: Gas Piping

DEFICIENCY 9.5
Flexible Gas Piping

Repair, Safety Issue: The gas supply line serving the furnace is flexible piping which passes through the outer case of the furnace without protection. This piping runs the risk of being damaged by the edge of the casing and should be replaced with rigid pipe or otherwise protected to prevent future leaks. A drip leg would also be required here.

Heating System

Heating: Combustion / Exhaust

DEFICIENCY 9.6
Flue Clearance

Repair, Safety Issue: There is insufficient clearance between the exhaust flue and combustible materials as noted (a minimum of 1" clearance is typically required). This is a fire hazard and should be corrected immediately by a qualified heating technician. Typically a metal collar is installed on the vent to prevent further movement and contact with adjoining materials.

Clean Ductwork (Older System)
Clean Ductwork (Older System)
Clean Ductwork (Older System)
Clean Ductwork (Older System)

Heating System

Heating: Ductwork

DEFICIENCY 9.7
Clean Ductwork (Older System)

Improve, Safety Issue: Due to the age of the ductwork and dust noted in the system, recommend having all supply and return lines vacuumed and cleaned to reduce dust and mold build-up in the systems, which can produce unhealthy air.

ADDITIONAL INFO - CUSTOM 9.8

Data Tag (Furnace/Heat Pump)

Reference photo(s) of manufacturer data tag(s).

ADDITIONAL INFO - CUSTOM 9.9

Air Filter Access Location

The air filter can be found at the location noted. Replacing the air filter with a new filter of the proper size on a regular basis can improve air quality and extend the life of the furnace/heat pump.

Heating System Info

  • General : Equipment Energy SourceNatural Gas
  • General : Heating System TypeForced Air Gas Furnace(s), Electronic Ignition
  • General : Btu Input (For Each Gas Furnace)100000
  • General : System BrandAMERICAN STANDARD
  • General : Vents/Flues/ChimneysPlastic PVC
  • General : Distribution MethodsDuctwork
  • General : Number Of SystemsOne
  • General : Other ComponentsFilter Location: Beside Furnace, Condensate Pump(s)
  • General : Furnace/Heat Pump Age (Typical Service Lifespan 18-20 Years)16
To view additional Heating System Photos, Click Here.

Plumbing System

Plumbing: Tubs / Showers

DEFICIENCY 10.1
Tub Stopper Repair

Repair: The tub stopper is inoperative or missing and needs repair or replacement altogether.

Plumbing System

Plumbing: Water Heaters

DEFICIENCY 10.2
Older Water Heater

Monitor, Future Repair: The water heater is an older unit that has lasted beyond its typical life span. It would be wise to replace this unit in the near future. One cannot predict with certainty when replacement will become necessary.

Plumbing System

Plumbing: Water Heaters

DEFICIENCY 10.3
Vent Pipe - Negative Slope

Repair, Safety Issue: The slope on the water heater vent pipe does not appear to be sufficient for proper venting of the exhaust gases. This should be checked and repaired as necessary.

Plumbing System

Plumbing: Water Heaters

DEFICIENCY 10.4
Expansion Tank Req'D For Tankless Heater?

Monitor, Possible Repair: There was no expansion tank or valve visible near the tankless water heater at the location pictured. Expansion devices are typically required to prevent the back up of hot water into the potable drinking water system and to prevent excessive pressure build-up in the piping systems. Some experts have contended that an expansion tank is not required for a tankless water heater. Recommend consulting with a qualified plumber concerning the need for this device and have installed as necessary.

ADDITIONAL INFO - CUSTOM 10.5

Water & Gas Shutoff Valves

Reference photos of water and gas shutoff valve locations.

ADDITIONAL INFO - CUSTOM 10.6

Data Tag (Water Heater)

Reference photo(s) of manufacturer data tag(s).

Plumbing System Info

  • General : Water Supply SourcePublic Water Supply (assumed - check with seller)
  • General : Service Pipe To HouseCopper (where visible)
  • General : Main Water Valve LocationGarage
  • General : Interior Supply Piping (Where Visible)Copper, Pressure Reducing Valve (PRV): Located at Main Water Shut-off
  • General : Waste SystemPublic Sewer System (Assumed - consult with seller)
  • General : Drain/Waste/Vent Piping (Where Visible)Plastic - PVC
  • General : Cleanout LocationFront Yard
  • General : Water HeaterGas Tankless Unit(s)
  • General : Water Heater Age (Typical Life 8-12 Years)17, mfr year: 2006
  • General : Water Heater CapacityTankless
  • General : Water Heater ManufacturerPaloma
  • General : Water Heater LocationGarage
  • General : Main Fuel Shut-Off Valve LocationLocated At Gas Meter (located: Right Side Yard)
  • General : Other ComponentsInterior Fire Sprinkler
To view additional Plumbing System Photos, Click Here.

Insulation / Ventilation

Insulation / Ventilation: Basement

DEFICIENCY 11.1
Run Dehumidifier In Basement

Improve: Recommend operating a dehumidifier in the basement area 24/7 to reduce unwanted humidity build-up, which can cause mold and mildew growth.

Insulation / Ventilation

Insulation / Ventilation: Fans

DEFICIENCY 11.2
Install Bath Fan (Improve)

Improve: Recommend installing an exhaust fan (in all bathrooms) vented to the exterior to help remove excessive humidity from this area, which can cause mold and mildew.

Insulation / Ventilation

Insulation / Ventilation: Windows and Doors

DEFICIENCY 11.3
Repair Door Weatherstripping

Repair: The weatherstripping is damaged and should be repaired or replaced as needed to limit outside air infiltration into conditioned areas.

Insulation / Ventilation Info

  • General : Exterior Wall InsulationNot Visible (R11 assumed)
  • General : Basement InsulationNot Totally Visible
  • General : Crawlspace InsulationN/A
  • General : Crawlspace VentilationN/A
  • General : Vapor RetardersHouse Wrap (assumed - not visible)
  • General : Exhaust Fan/Vent LocationsBathroom(s), Laundry/Dryer
To view additional Insulation / Ventilation Photos, Click Here.

Interior Components

Interior: Ceilings / Walls

DEFICIENCY 12.1
Previous Patching Noted

Monitor: Previous damage was noted in the walls/ceilings, which has been repaired. Consult with seller concerning history of past leaks or settlement here.

Interior Components

Interior: Flooring

DEFICIENCY 12.2
Toe Trip Hazard

Repair, Safety Issue: The transition at the top of the steps at the carpet and flooring as noted poses a tripping hazard and should altered for proper safety.

Interior Components

Interior: Windows

DEFICIENCY 12.3
Bedroom Windows Painted Shut

Repair, Safety Issue: A majority of the windows are painted or otherwise stuck shut. Present day safety standards require at least one operable window per bedroom for emergency egress and ventilation.

Fogged Glass
Fogged Glass
Fogged Glass
Fogged Glass
Fogged Glass

Interior Components

Interior: Windows

DEFICIENCY 12.4
Fogged Glass

Repair: "Fogged" glass was noted, which should be replaced. This condition is typically caused by damaged seals around the perimeter of the insulated glass, which in turn allows condensation to develop between the panes. All damaged glass panels in this area should be replaced by a qualified glass replacement contractor to prevent further moisture damage to wood components and for proper visibility through the glass. The contractor should inspect all other insulated panels in the house for additional condensation that may be occurring in the glass. Other windows may be fogged but cannot be positively determined until the glass is cleaned.

Seal Interior Of Cabinets
Seal Interior Of Cabinets

Interior Components

Interior: Cabinetry

DEFICIENCY 12.5
Seal Interior Of Cabinets

Repair: The inside panels of the cabinets as noted should be repaired and sealed to prevent the infiltration of outside air and insects.

Interior Components

Interior: Stairways

DEFICIENCY 12.6
Handrail Missing

Repair, Safety Issue: Handrails are required when there are four or more steps. Add handrail for proper safety.

Interior Components

Interior: Basement

DEFICIENCY 12.7
Run Dehumidifier

Improve: Recommend operating a dehumidifier in the basement area 24/7 to reduce unwanted humidity build-up, which can cause mold and mildew growth.

Interior Components

Interior: Environmental Issues

DEFICIENCY 12.8
Radon Note (No Test)

Monitor, Safety Issue: Radon gas is a naturally occurring gas that is invisible, odorless and tasteless, and has been found to be a risk when the gas percolates through the ground and enters an enclosed structure. The Environmental Protection Agency (E.P.A.) states that a radon reading of more than 4.0 picoCuries per liter of air represents a health hazard and can lead to a higher incidence of cancer. The EPA recommends that all houses be tested for radon.  A radon evaluation is beyond the scope of this inspection (unless specifically requested). For more information, consult the Environmental Protection Agency (E.P.A.) or visit http://www.epa.gov/iaq/radon/.

Interior Components Info

  • General : Wall And Ceiling MaterialsSheetrock, Stippled Ceilings
  • General : Floor SurfacesCarpet, Laminate
  • General : Shower And Tub SurroundsFiberglass
  • General : Windows And GlazingDouble Hung, Fixed Pane, Double Pane
  • General : DoorsComposite, Bi-fold Doors
  • General : Home Security: Number Of Floors W/Bedrooms2
To view additional Interior Components Photos, Click Here.
Fireplace Servicing Needed?
Fireplace Servicing Needed?

Appliances / Fireplaces

Fireplaces

DEFICIENCY 13.1
Fireplace Servicing Needed?

Possible Repair, Safety Issue: Since the chimney flue(s) are not entirely visible, we recommend that you consult with the seller concerning recent inspections and cleaning performed on the fireplace components and have this performed before closing as needed. Fireplaces and chimneys should be inspected and cleaned once a year under normal usage.

Appliances / Fireplaces

Fireplaces

DEFICIENCY 13.2
Gas Logs Turned Off

Monitor: Check with the seller concerning the proper operation of the gas logs as the pilot was not lit at the time of the inspection, which prevented the testing of this appliance.

Appliances / Fireplaces

Appliances: Cooktop / Oven

DEFICIENCY 13.3
Anti-Tip Device Needed

Repair, Safety Issue: There was no apparent anti-tip device installed for the oven/range unit, which should be added as needed to prevent the range from tipping when the doors are open.

Appliances / Fireplaces

Appliances: Disposal

DEFICIENCY 13.4
Disposal Inoperative?

Monitor, Possible Repair: The waste disposal did not turn on with the switch nearby and is either inoperative or not connected. Check with the seller concerning another switch location and it's proper operation and have repaired if needed.

Damage Noted
Damage Noted
Damage Noted
Damage Noted
Damage Noted

Appliances / Fireplaces

Appliances: Refrigerator / Ice Maker

DEFICIENCY 13.5
Damage Noted

Repair: Several items were noted as damaged on the refrigerator: freezer exterior handle, interior door shelves, ice maker.

Appliances / Fireplaces

Appliances: Dryer / Washing Machine

DEFICIENCY 13.6
Flexible Vent Piping Noted

Improve, Safety Issue: The flexible clothes dryer exhaust vent pipe as noted should be replaced with rigid smooth wall piping where possible to prevent lint build-up in the line which can cause damage and possible fires at the dryer element.

Appliances / Fireplaces

Appliances: Dryer / Washing Machine

DEFICIENCY 13.7
Clean Dryer Vent

Repair, Safety Issue: The clothes dryer exhaust vent pipe appears clogged with lint and should be cleaned. Blocked piping can cause damage and possible fires at the dryer element.

Appliances / Fireplaces

Appliances: Kitchen Exhaust

DEFICIENCY 13.9
Exhaust Fan Vents Into Kitchen

Improve: The cooktop hood fan currently vents into the kitchen should ideally be improved to exhaust to the building exterior.

Appliances / Fireplaces

Appliances: Microwave

DEFICIENCY 13.10
Microwave Light Inoperative

Repair: The light did not operate when tested using standard controls. Replace bulb and test; consult an appliance repair technician for more involved repairs.

Appliances / Fireplaces Info

  • General : Appliances TestedElectric Range / Oven, Microwave Oven (with built-in fan - vents into kitchen), Dishwasher, Refrigerator (with ice-maker), Garbage Disposal
  • General : Laundry Facility240 Volt Circuit for Dryer (3 Pronged Plug), Gas Piping for Dryer, Hot and Cold Water Supply for Washer, Waste Standpipe for Washer, Dryer Vented to Building Exterior
  • General : Other ComponentsDoor Bell, Security System (not tested)
  • General : FireplacesMetal Firebox (with Masonry Insert), Damper, Automatic Gas Logs
To view additional Appliances / Fireplaces Photos, Click Here.

Termite, Rodent, Insect and Pest Activity Info

  • General : Wood Destroying Organism (Wdo) ActivityNone noted

Post Inspection Checklist Info

  • Appliances : Ovens And RangesTurned Off
  • Appliances : DishwasherTurned Off, Drained
  • Appliances : Refrigerators And FreezersClosed, Functioning
  • Appliances : Microwave OvenTurned Off
  • Appliances : Garbage DisposalNot working, see comments
  • Appliances : Clothes WasherNone
  • Appliances : Clothes DryerNone