Residential Inspection Report

13867 Firefall Court

Colorado Springs, Colorado 80921

Year Built : 2006 Sq.Footage : 3027 Occupied : Vacant Utilities : Water, Electric, On Weather : Clear
  • Summary

    487 Items Inspected

    DEFECT #0 OF 0

    Roof Coverings and Drainage

    Coverings

    DEFICIENCY 2.1
    Chipped and Loose Tiles

    Estimated Severity : Minor/Maintenance

    The roof had some chipped and loose tiles. I recommend a qualified roof contractor repair or replace to p...

    Exterior

    Walkways Patios Driveways

    DEFICIENCY 3.1
    Cracking/Settling - Minor - Walkways Patios Driveways

    Estimated Severity : Minor/Maintenance

    I observed some minor cracks in the cement. This is very typical due to soil movement. I would consider ...

    Exterior

    Siding Flashing Trim

    DEFICIENCY 3.2
    Cracking Stucco - Minor

    Estimated Severity : Minor/Maintenance

    The stucco siding showed cracking in one or more places. This is a result of temperature changes, and ty...

    Exterior

    Siding Flashing Trim

    DEFICIENCY 3.3
    Cracking in stone veneer

    Estimated Severity : ⚠️ Repair

    At the time of inspection, some cracking was noted in the stone veneer. This is not a structural componen...

    Exterior

    Exterior Doors

    DEFICIENCY 3.4
    Paint / Finish Maintenance - Exterior Doors

    Estimated Severity : ⚠️ Repair

    While inspecting the exterior door, it appeared to need the finish maintained. I recommend having the doo...

    Exterior

    Exterior Doors

    DEFICIENCY 3.5
    No deadbolt - Exterior Doors

    Estimated Severity : ⚠️ Repair

    No dead bolt on the exterior door. I recommend installing for safety on all exterior doors.

    Garage

    Non-Fire Rated Walls & Ceilings

    DEFICIENCY 4.1
    Water Stains - Non-Firewall Garage

    Estimated Severity : ⚠️ Repair

    Ceiling had water stains indicative of leaks or condensation. There are no active leaks as moisture level...

    Electrical

    GFCI AFCI

    DEFICIENCY 5.1
    GFCI Protection Not Installed

    Estimated Severity : 📛 Potential Safety Concern

    There are receptacles in the home that aren't protected by GFCI when they should be. Receptacles near wat...

    Cooling

    Cooling Equipment

    DEFICIENCY 8.1
    Insulation Damaged/Missing - AC Condenser

    Estimated Severity : Minor/Maintenance

    Recommend fully insulating coolant line for the AC condenser.

    Doors Windows Interior

    General

    DEFICIENCY 10.1
    Damage drywall

    Estimated Severity : ⚠️ Repair

    minor drywall damage was present at time of inspection

    Doors Windows Interior

    Doors

    DEFICIENCY 10.2
    Sticks - Interior Door

    Estimated Severity : ⚠️ Repair

    I found one or more doors that stick and is difficult to open and close. I recommend adjustment of doors ...

    Doors Windows Interior

    Windows

    DEFICIENCY 10.3
    Caulk Maintenance - Window

    Estimated Severity : ⚠️ Repair

    I did find one or more windows in the home that need to be caulked on the interior side. Caulking on the ...

    Doors Windows Interior

    Floors

    DEFICIENCY 10.4
    Stains - Carpet

    Estimated Severity : ⚠️ Repair

    When I inspected the home's flooring, I found areas of the carpet that appeared to have stains or some ty...

    Doors Windows Interior

    Floors

    DEFICIENCY 10.5
    Moisture Damage - Flooring

    Estimated Severity : ⚠️ Repair

    When inspecting the home's flooring, one or more areas had visible moisture damage. I recommend a qualifi...

    Doors Windows Interior

    Floors

    DEFICIENCY 10.6
    Re-stretch Carpet

    Estimated Severity : Minor/Maintenance

    The carpet may need to be re stretched recommend repair as needed.

    Doors Windows Interior

    Walls

    DEFICIENCY 10.7
    Moisture damage on walls

    Estimated Severity : ⚠️ Repair

    There appears to be moisture damage on walls. Recommend further evaluation to correct the source of moist...

    Doors Windows Interior

    Ceilings

    DEFICIENCY 10.8
    Patching - Ceiling

    Estimated Severity : ⚠️ Repair

    There appears to be some visible patching in the ceiling. Recommend asking the seller history as to why t...

    Insulation Ventilation

    Attic Insulation

    DEFICIENCY 12.1
    Aged Insulation - Attic

    Estimated Severity : ⚠️ Repair

    Due to the age of the Insulation, and most likely the original install of the home, I recommend a insulat...

Report Remarks

A home inspection is a non-invasive, visual examination of the accessible areas of the property, designed to identify areas of concern within specific systems or components defined by the signed agreements and Standards of Practice, that are both observed and deemed material by the inspector at the exact date and time of inspection. Any and all recommendations for repair, replacement, evaluation, and maintenance issues found, should be evaluated by the appropriate trades contractors within the client's inspection contingency window or prior to closing, which is contract applicable, in order to obtain proper dollar amount estimates on the cost of said repairs and also because these evaluations could uncover more potential issues than are able to be noted from a purely visual inspection of the property.

This inspection will not reveal every concern or issue that exists, but only those material defects that were observable on the day of the inspection. This inspection is intended to assist in evaluating the overall condition of the dwelling only. A Home Inspection is not a code inspection. We recommend that you check with your local building department for any closed, voided, failed or unpermitted work prior to closing on the home. This inspection does not predict future conditions and conditions with the property are subject to change the moment we leave the premises.

A home inspection is designed to reflect, as accurately as possible, the visible condition of the home at the time of the inspection. Conditions of a home for sale can change radically in only a day or two, so a home inspection is not meant to guarantee the condition of the home on the date of the sale, for example. It’s not uncommon for conditions to change between the time of the inspection and the closing date.

This chart details the predicted life expectancy of household materials, systems, and components. Life expectancy varies with usage, weather, installation, maintenance, and quality of materials. This chart provides a general guideline from the world's largest inspection association https://www.nachi.org/life-expectancy.htm

To review our Standards of Practice, view... https://www.nachi.org/sop.htm

Inspection Details Info

  • General : In AttendanceClient, Buyer Agent
  • General : OccupancyVacant
  • General : Style of HomeRanch, With Basement
  • General : UtilitiesWater, Electric, On
  • General : WeatherClear
  • General : Temperature77
Chipped and Loose Tiles
Chipped and Loose Tiles

Roof Coverings and Drainage

Coverings

DEFICIENCY 2.1
Chipped and Loose Tiles

Estimated Severity : Minor/Maintenance

The roof had some chipped and loose tiles. I recommend a qualified roof contractor repair or replace to prevent moisture intrusion.

Roof Coverings and Drainage Info

  • General : Inspection MethodRoof
  • General : Roof Type / StyleHip
  • Coverings : MaterialTile
  • Roof Drainage Systems : Gutter MaterialAluminum
  • Flashings : MaterialSteel
  • Skylights, Chimneys & Other Roof Penetrations : Plumbing VentsYes, Satisfactory
  • Skylights, Chimneys & Other Roof Penetrations : Roof VentsYes, Satisfactory
  • Skylights, Chimneys & Other Roof Penetrations : Vents (Bathroom, Laundry)Yes, Satisfactory
  • Skylights, Chimneys & Other Roof Penetrations : SkylightNo
  • Skylights, Chimneys & Other Roof Penetrations : ChimneyYes, Satisfactory
  • Skylights, Chimneys & Other Roof Penetrations : FlueYes, Satisfactory
  • Skylights, Chimneys & Other Roof Penetrations : Roof Safety AnchorsNo
  • Skylights, Chimneys & Other Roof Penetrations : Swamp CoolerNo
  • Skylights, Chimneys & Other Roof Penetrations : SolarNo
To view additional Roof Coverings and Drainage Photos, Click Here.

Exterior

Walkways Patios Driveways

DEFICIENCY 3.1
Cracking/Settling - Minor - Walkways Patios Driveways

Estimated Severity : Minor/Maintenance

I observed some minor cracks in the cement. This is very typical due to soil movement. I would consider these cracks cosmetic, but I do recommend using a sealant to prevent water intrusion. Monitor and maintain as necessary.

Cracking Stucco - Minor
Cracking Stucco - Minor
Cracking Stucco - Minor

Exterior

Siding Flashing Trim

DEFICIENCY 3.2
Cracking Stucco - Minor

Estimated Severity : Minor/Maintenance

The stucco siding showed cracking in one or more places. This is a result of temperature changes, and typical as homes age. I recommend patching, sealing, replacing, or monitoring areas of cracking depending on severity and siding material in question.

Exterior

Siding Flashing Trim

DEFICIENCY 3.3
Cracking in stone veneer

Estimated Severity : ⚠️ Repair

At the time of inspection, some cracking was noted in the stone veneer. This is not a structural component of the home. Recommend performing any necessary maintenance for the upkeep of the stone exterior..

Exterior

Exterior Doors

DEFICIENCY 3.4
Paint / Finish Maintenance - Exterior Doors

Estimated Severity : ⚠️ Repair

While inspecting the exterior door, it appeared to need the finish maintained. I recommend having the door properly finished in order to protect the door from sun and water damage.

Exterior

Exterior Doors

DEFICIENCY 3.5
No deadbolt - Exterior Doors

Estimated Severity : ⚠️ Repair

No dead bolt on the exterior door. I recommend installing for safety on all exterior doors.

Exterior Info

  • General : Inspection MethodVisual
  • Walkways Patios Driveways : Driveway MaterialConcrete
  • Siding Flashing Trim : Siding MaterialStone, Stucco
  • Siding Flashing Trim : Siding StyleStone
  • Eaves Soffits Fascia : MaterialWood
  • Exterior Doors : Exterior Entry Door TypesSteel, Sliding Glass Door
  • Windows : WindowsVinyl
  • Decks Balconies Porches Steps : StructurePatio
  • Decks Balconies Porches Steps : MaterialConcrete
  • Fence : FenceNo
To view additional Exterior Photos, Click Here.

Garage

Non-Fire Rated Walls & Ceilings

DEFICIENCY 4.1
Water Stains - Non-Firewall Garage

Estimated Severity : ⚠️ Repair

Ceiling had water stains indicative of leaks or condensation. There are no active leaks as moisture levels were normal. Recommend monitoring.

Garage Info

  • General : AttachedYes
  • General : DetachedNo
  • General : CarportNo
  • Floor : MaterialConcrete
  • Non-Fire Rated Walls & Ceilings : Type of wallExposed wall
  • Fire Rated Walls & Ceilings : Fire wall conditionSatisfactory
  • Garage Door : MaterialWood Composite
  • Garage Door : TypeSectional
  • Garage Door Opener & Safety : Resistance SettingsFunctioning
  • Garage Door Opener & Safety : Sensor Height - Garage Door OpenerGood
  • Garage Door Opener & Safety : SensorsFunctioning
  • Occupant Door (From garage to inside of home) : Fire DoorYes
To view additional Garage Photos, Click Here.

Electrical

GFCI AFCI

DEFICIENCY 5.1
GFCI Protection Not Installed

Estimated Severity : 📛 Potential Safety Concern

There are receptacles in the home that aren't protected by GFCI when they should be. Receptacles near water sources, in garages, and outside need to be GFCI in order to prevent accidental shocks. I recommend having an electrician evaluate the home's receptacles in order to ensure safety.Here is a link to read about how GFCI receptacles keep you safe.

Electrical Info

  • Service Entrance Conductors : Electrical Service Conductors240V
  • Main Subpanels Service Grounding Main Overcurrent Device : Main Panel LocationGarage
  • Main Subpanels Service Grounding Main Overcurrent Device : Panel Capacity200 AMP
  • Main Subpanels Service Grounding Main Overcurrent Device : Panel ManufacturerCutler Hammer
  • Main Subpanels Service Grounding Main Overcurrent Device : Panel TypeCircuit Breaker, AFCI Breakers
  • Main Subpanels Service Grounding Main Overcurrent Device : Sub Panel LocationNone
  • Branch Wiring Circuits Breakers Fuses : Branch WiringCopper, Aluminum Strand
  • Branch Wiring Circuits Breakers Fuses : Wiring MethodRomex
  • GFCI AFCI : Location testedIn The Panel, On outlets
  • Lighting Fixtures Switches Receptacles : Represenative Number TestedYes, Marginal
  • Lighting Fixtures Switches Receptacles : Ceiling fansYes, Satisfactory
  • Smoke Detectors : Type of smoke detectorsHardwired
  • Carbon Monoxide Detectors : Type of COceiling
To view additional Electrical Photos, Click Here.

Foundation and Structure Info

  • General : Inspection MethodVisual
  • Foundation : MaterialConcrete
  • Foundation : StyleBasement
  • Floor / Ceiling Structure : MaterialInaccessible
  • Floor / Ceiling Structure : Sub-floorInaccessible
  • Floor / Ceiling Structure : Basement/Crawlspace FloorConcrete, Unobservable
  • Wall Structure : wall construction typeFloating Walls, not visibile
  • Wall Structure : Material2 x 4 Wood Studs
  • Roof Structure : Decking MaterialOSB
  • Roof Structure : Truss TypeManufactured Truss
To view additional Foundation and Structure Photos, Click Here.

Heating Info

  • General : AFUE RatingAFUE (Annual fuel utilization efficiency) is a metric used to measure furnace efficiency in converting fuel to energy. A higher AFUE rating means greater energy efficiency. 90% or higher meets the Department of Energy's Energy Star program standard.
  • Equipment : BrandCarrier
  • Equipment : Energy SourceGas
  • Equipment : Heat TypeForced Air
  • Normal Operating Controls : ThermostatYes
  • Distribution Systems : DuctworkNon-insulated, Non-observable
  • Presence of Installed Heat Source in Each Room : LocationCeiling
  • Presence of Installed Heat Source in Each Room : TypeRegister
  • Gas/LP Firelogs & Fireplaces : Working conditionYes, Teseted
To view additional Heating Photos, Click Here.

Cooling

Cooling Equipment

DEFICIENCY 8.1
Insulation Damaged/Missing - AC Condenser

Estimated Severity : Minor/Maintenance

Recommend fully insulating coolant line for the AC condenser.

Cooling Info

  • Cooling Equipment : BrandCarrier
  • Cooling Equipment : Energy Source/TypeElectric, Central Air Conditioner
  • Cooling Equipment : LocationLeft Side of Home
  • Cooling Equipment : SEER Ratingunknown
  • Normal Operating Controls : ThermostatYes
  • Distribution System : ConfigurationCentral
  • Presence of Installed Cooling Source in Each Room : LocationCeiling, Floor Surface
To view additional Cooling Photos, Click Here.

ADDITIONAL INFO - CUSTOM 9.1

Main Water Shut-Off

This valve turns the water off to the whole house.

Plumbing Info

  • General : FiltersNone
  • General : Water SourcePublic
  • Main Water Shut-off : LocationBasement
  • Drain, Waste, & Vent Systems : Drain Size1 1/2", 2", 3"
  • Drain, Waste, & Vent Systems : MaterialPVC
  • Water Supply : Distribution MaterialCopper
  • Water Supply : Water Supply MaterialCopper
  • Water Heater : ManufacturerRheem
  • Water Heater : Power Source/TypeGas
  • Water Heater : Capacity50
  • Water Heater : LocationBasement
  • Water Heater : Hot Water Function at FixtureWorking
  • Gas Supply : Main Gas Shut-Off LocationGas Meter
  • Fixtures : funtioning at the time of the InspectionYes, Satisfactory
  • Sump Pump : LocationSealed, Front of the home
To view additional Plumbing Photos, Click Here.

Doors Windows Interior

General

DEFICIENCY 10.1
Damage drywall

Estimated Severity : ⚠️ Repair

minor drywall damage was present at time of inspection

Doors Windows Interior

Doors

DEFICIENCY 10.2
Sticks - Interior Door

Estimated Severity : ⚠️ Repair

I found one or more doors that stick and is difficult to open and close. I recommend adjustment of doors so they operate smoothly. Here is a helpful DIY article on how to fix a sticking door.

Doors Windows Interior

Windows

DEFICIENCY 10.3
Caulk Maintenance - Window

Estimated Severity : ⚠️ Repair

I did find one or more windows in the home that need to be caulked on the interior side. Caulking on the interior side is not only for cosmetic reasons, but also to weatherize the window. I recommend using a flexible and paintable caulking, and maintain over the years. 

Doors Windows Interior

Floors

DEFICIENCY 10.4
Stains - Carpet

Estimated Severity : ⚠️ Repair

When I inspected the home's flooring, I found areas of the carpet that appeared to have stains or some type of discoloration. I recommend a thorough steam clean by a qualified carpet cleaning company. 

Doors Windows Interior

Floors

DEFICIENCY 10.5
Moisture Damage - Flooring

Estimated Severity : ⚠️ Repair

When inspecting the home's flooring, one or more areas had visible moisture damage. I recommend a qualified flooring contractor evaluate & repair areas of moisture.

Doors Windows Interior

Floors

DEFICIENCY 10.6
Re-stretch Carpet

Estimated Severity : Minor/Maintenance

The carpet may need to be re stretched recommend repair as needed.

Doors Windows Interior

Walls

DEFICIENCY 10.7
Moisture damage on walls

Estimated Severity : ⚠️ Repair

There appears to be moisture damage on walls. Recommend further evaluation to correct the source of moisture and repair drywall

Doors Windows Interior

Ceilings

DEFICIENCY 10.8
Patching - Ceiling

Estimated Severity : ⚠️ Repair

There appears to be some visible patching in the ceiling. Recommend asking the seller history as to why the patching was needed. 

Doors Windows Interior Info

  • Doors : ConditionSatisfactory but may need future adjustment
  • Windows : Window TypeSingle-hung, Sliders, Double Pane non opening
  • Windows : Window ManufacturerAmsco
  • Floors : Floor CoveringsCarpet, Hardwood, Tile
  • Walls : Wall MaterialPlaster, Tile
  • Ceilings : Ceiling MaterialDrywall, Textured
  • Steps, Stairways & Railings : Locationbasement
  • Countertops & Cabinets : Countertop MaterialGranite, Quartz
  • Countertops & Cabinets : CabinetryWood
To view additional Doors Windows Interior Photos, Click Here.

Appliances Info

  • Dishwasher : BrandGE
  • Refrigerator : BrandSamsung
  • Refrigerator : Ice and Water DispenserYes, Tested, Operable
  • Refrigerator : Working at Time of InspectionYes, Tested, Operable
  • Range/Oven/Cooktop : Range/Oven Energy SourceGas
  • Range/Oven/Cooktop : Range/Oven BrandSamsung
  • Range/Oven/Cooktop : Exhaust Hood TypeRe-circulate
  • Range/Oven/Cooktop : Working at Time of Inspection Range/Oven/CooktopYes
  • Range Hood : FunctioningYes
  • Built-in Microwave : BrandSamsung
  • Built-in Microwave : Working at time of inspection - Built-in MicrowaveYes
  • Garbage Disposal : Working conditionYes
  • Clothes Dryer : BrandKenmore
  • Clothes Dryer : Power Source220V Electric
  • Clothes Dryer : Vent MethodMetal - Flex
  • Clothes Dryer : Working condition at time of inspectionYes
  • Clothes Washer : BrandKenmore
  • Clothes Washer : Working condition at time of inspectionYes
To view additional Appliances Photos, Click Here.

Insulation Ventilation

Attic Insulation

DEFICIENCY 12.1
Aged Insulation - Attic

Estimated Severity : ⚠️ Repair

Due to the age of the Insulation, and most likely the original install of the home, I recommend a insulation specialist to verify the quality and condition of the insulation. Overtime, insulation settles and compresses. I recommend further evaluation to determine if newer insulation is necessary to improve the efficiency of your home.

Insulation Ventilation Info

  • Crawlspace / Basement Wall Insulation : R-Value11
  • Crawlspace / Basement Wall Insulation : Insulation TypeBatt
  • Flooring Insulation : Insulation TypeUnobservable
  • Exterior / Interior Wall Insulation : R-Value13
  • Exterior / Interior Wall Insulation : Insulation TypeBatt
  • Attic Insulation : Insulation TypeBlown, Fiberglass
  • Attic Insulation : R-Value30
  • Ventilation : Ventilation TypeSoffit Vents, Roof Vents
  • Exhaust Systems : Exhaust FansFan Only
  • Radon Mitigation System : Conditionnone
To view additional Insulation Ventilation Photos, Click Here.

ADDITIONAL INFO - CUSTOM 13.1

Sewer Scope Videos

Video of sewer line

Lateral Sewer Line Info

  • Sewer Scope : Distance Scoped71
  • Sewer Scope : LocationsClean-out Exterior
  • Sewer Scope : Pipe MaterialPVC
  • Sewer Scope : Overall ConditionGood

ADDITIONAL INFO - CUSTOM 14.1

Radon Results

Radon results

Radon Testing Info

  • Test Results : LocationBasement Bedroom
  • Test Results : Duration of Test48 hrs
  • Test Results : Time set10
  • Test Results : Average Radon Level3.83
  • Test Results : Mitigation SystemNot Present
  • Test Results : SummaryA full PDF breakdown of the radon test results is attached to this report.