Precision Residential

123 Sample Drive

Anytown , USA 54321

Year Built : 1983 Sq.Footage : 3189 Occupied : Furnished, Occupied Utilities : Water, Gas, Electric, On Weather : Clear
  • Summary

    DEFECT #0 OF 0

    Attic

    Attic: Roof Structure

    DEFICIENCY 2.1
    Water Stains Noted - Dry At Inspection

    Monitor: Water staining noted. The area was dry at the time of inspection. Consult the owner for further...

    Attic

    Attic: Insulation / Ventilation

    DEFICIENCY 2.2
    Microbial Growth Noted In Attic

    Repair: Microbial growth was noted on attic components, likely due to a combination of high humidity and...

    Attic

    Attic: Stairways / Access

    DEFICIENCY 2.3
    Adjust Pull-Down Stairs

    Repair, Safety Issue: The pull-down stairs to the attic need to be adjusted so that the stair is in a str...

    Garage

    Exterior: Garage

    DEFICIENCY 3.3
    Impact Reverse Adjustment Needed

    Repair, Safety Issue: The garage door opener did not automatically reverse using standard testing procedu...

    Structural Components

    Structural: Crawlspace

    DEFICIENCY 4.1
    Water Staining At Foundation

    Repair, Monitor: Evidence of previous or active moisture penetration was observed in the crawlspace, espe...

    Structural Components

    Structural: Floor Structure

    DEFICIENCY 4.4
    Water Damage / Rot Noted - Repair

    Repair: The floor structure as noted shows evidence of advanced water damage and rotting. Rot weakens the...

    Exterior Components

    Exterior Veneer: Stucco

    DEFICIENCY 6.1
    Previous Stucco Repairs Noted

    Monitor: Previous repairs to the exterior EIFS veneer were noted, which align with interior drywall repa...

    Exterior Components

    Exterior Veneer: Stucco

    DEFICIENCY 6.2
    EIFS Warning

    Monitor, Possible Concern: EIFS (Exterior Insulation and Finish System - sometimes referred to as "Synthe...

    Exterior Components

    Exterior Veneer: Stucco

    DEFICIENCY 6.3
    EIFS Grade Contact

    Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and ...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.6
    Bolts At Ledger Band Inadequate

    Repair, Safety Issue: The bolts attaching the deck ledger to the structure of the house appear to be inad...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.7
    Deck Railing Picket Spacings

    Repair, Safety Issue: The openings between pickets of the deck railing is more than allowed by present da...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.8
    Handrail Graspability

    Repair, Safety Issue: The handrails as noted do not meet current safety standards for proper grasping of ...

    Exterior Components

    Exterior: Decks

    DEFICIENCY 6.9
    Landing Needed At Deck Stairs

    Improve, Safety Issue: Deck stairs should terminate at a concrete landing to prevent tripping or falling....

    Exterior Components

    Exterior: Driveway / Sidewalks

    DEFICIENCY 6.13
    Walkway Trip Hazard

    Improve, Safety Issue: The walkway as noted presents a trip hazard and should be altered as needed for im...

    Exterior Components

    Exterior: Retaining Walls

    DEFICIENCY 6.14
    Guardrail Needed At Retaining Wall

    Repair, Safety Issue: Current safety standards require a guardrail for walking areas that are more than 3...

    Electrical System

    Electrical: Panels

    DEFICIENCY 7.1
    Label Panel

    Improve: The circuits in the electrical panel box should be labeled for proper identification of the equi...

    Electrical System

    Electrical: Panels

    DEFICIENCY 7.4
    Advanced Age Of Panel

    Improve: The electrical panel appears to be an older model that may be reaching the end of its servicabl...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.5
    Loose Outlet

    Repair: Loose outlet(s) as noted should be tightened to prevent the loosening of the wiring connections i...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.7
    GFCI Recommended

    Improve, Safety Issue: The installation of a ground fault circuit interrupter outlet(s) is recommended at...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.8
    GFCI Needed At Whirlpool Bath

    Possible Repair, Safety Issue: A ground fault circuit interrupter (GFCI) should be installed on the circu...

    Electrical System

    Electrical: Outlets

    DEFICIENCY 7.9
    Cover Missing At Floor Outlet

    Repair, Safety Issue: Floor outlets are required to be sealed when not in use. Consult a handy person pe...

    Cooling System

    Cooling: Central Air System

    DEFICIENCY 8.1
    A/C Units Built Prior To 2010 Will Need Replacement

    Monitor, Future Repair:  The outdoor condensing unit(s) at the location pictured appear to have been man...

    Heating System

    Heating: Combustion / Exhaust

    DEFICIENCY 9.2
    Flue Clearance

    Repair, Safety Issue: There is insufficient clearance between the exhaust flue and combustible materials ...

    Plumbing System

    Plumbing: Gas Supply

    DEFICIENCY 10.2
    Rust At Gas Piping

    Repair: Rust can lead to deterioration and possibly leakage of the gas piping. Sand and paint with Rusto...

    Plumbing System

    Plumbing: Drain / Waste / Vent (DWV) Piping

    DEFICIENCY 10.5
    Septic System Noted

    Monitor, Possible Repair: Based on the amount of usage, septic tanks typically need servicing and cleanin...

    Plumbing System

    Plumbing: Water Heaters

    DEFICIENCY 10.12
    TPR Piping Needs Bleeder Valve

    Repair, Safety Issue: Current safety standards in the state of GA allow discharge piping for the TPR (Te...

    Insulation / Ventilation

    Insulation / Ventilation: Crawlspace

    DEFICIENCY 11.1
    Improve Ventilation In Crawlspace (Monitor)

    Monitor: Ventilation of the crawl space may be insufficient. A full vapor barrier and dehumidifer were no...

    Insulation / Ventilation

    Insulation / Ventilation: Crawlspace

    DEFICIENCY 11.3
    Dehumidifier Inoperative

    Repair: The permanent dehumidifier installed in the crawlspace was not operative at the time of inspecti...

    Interior Components

    Interior: Ceilings / Walls

    DEFICIENCY 12.1
    Repairs Noted

    Monitor: Previous repairs were noted. Consult the seller for history of damage and repairs, and monitor...

    Interior Components

    Interior: Environmental Issues

    DEFICIENCY 12.5
    Radon Note (Test In Progress)

    Monitor, Safety Issue: Radon gas is a naturally occurring radioactive gas that is invisible, odorless and...

    Appliances / Fireplaces

    Fireplaces

    DEFICIENCY 13.1
    Fireplace Cleaning (With Gas Logs)

    Repair, Safety Issue: The fireplace chimney could use cleaning due to the presence of built-up soot in th...

    Appliances / Fireplaces

    Fireplaces

    DEFICIENCY 13.2
    Install Damper Clamp For Gas Logs

    Improve, Safety Issue: There was no clamp installed at the metal damper above the gas logs in the firepla...

    Appliances / Fireplaces

    Appliances: Cooktop / Oven

    DEFICIENCY 13.3
    Gas Shut-Off Valve Needed

    Repair, Safety Issue: There does not appear to be a gas shut-off valve below the cooktop, which should be...

    Appliances / Fireplaces

    Appliances: Cooktop / Oven

    DEFICIENCY 13.4
    Flexible Gas Piping Noted At Cooktop

    Improve: Flexible gas piping can be prone to mechanical damage and leakage. Use caution when placing ite...

    Appliances / Fireplaces

    Appliances: Dryer / Washing Machine

    DEFICIENCY 13.5
    Flexible Vent Piping Noted At Dryer

    Improve, Safety Issue: The flexible clothes dryer exhaust vent pipe as noted should be replaced semi-rigi...

    Appliances / Fireplaces

    Appliances: Dryer / Washing Machine

    DEFICIENCY 13.6
    Clean Dryer Vent

    Repair, Safety Issue: The clothes dryer exhaust vent pipe appears clogged with lint and should be cleaned...

    Appliances / Fireplaces

    Appliances: Other Equipment

    DEFICIENCY 13.9
    Outdoor Grill Igniter Inoperative

    Repair: The electronic igniter for the outdoor grill did not work when tested using normal controls. Con...

Report Remarks

To review our Standards of Practice, view... https://www.homeinspector.org/Resources/Standard-of-Practice/

Occupied / Furnished Disclaimer
Occupied / Furnished Disclaimer

Inspection Details

General

LIMITATION 1.1
Occupied / Furnished Disclaimer

Due to the home being furnished at the time of inspection, not all floor and wall surfaces, countertops, windows, and electrical receptacles could be inspected or tested.

Inspection Details Info

  • General : In AttendanceClient, Owner
  • General : OccupancyFurnished, Occupied
  • General : Style Of HomeRanch, With Crawlspace
  • General : UtilitiesWater, Gas, Electric, On
  • General : WeatherClear, Temperature approximately 80 degrees F
To view additional Inspection Details Photos, Click Here.
Water Stains Noted - Dry At Inspection
Water Stains Noted - Dry At Inspection
Water Stains Noted - Dry At Inspection

Attic

Attic: Roof Structure

DEFICIENCY 2.1
Water Stains Noted - Dry At Inspection

Monitor: Water staining noted. The area was dry at the time of inspection. Consult the owner for further information regarding past leakage, repairs, and warranty information. Consult a qualified roofer for additional evaluation and repairs as needed.

Microbial Growth Noted In Attic
Microbial Growth Noted In Attic
Microbial Growth Noted In Attic
Microbial Growth Noted In Attic

Attic

Attic: Insulation / Ventilation

DEFICIENCY 2.2
Microbial Growth Noted In Attic

Repair: Microbial growth was noted on attic components, likely due to a combination of high humidity and lack of ventilation. Attempt to clean and increase ventilation. Consult a mold remediation specialist for evaluation and mitigation if needed.

Attic

Attic: Stairways / Access

DEFICIENCY 2.3
Adjust Pull-Down Stairs

Repair, Safety Issue: The pull-down stairs to the attic need to be adjusted so that the stair is in a straight line when fully extended (see manufacturer's recommendations printed on label). This will relieve unnecessary pressure on the connections at the folding sections. The stairs should be cut back at the floor to provide proper support.

Attic Info

  • General : Attic AccessAccessible via Pull Down Stairs, Accessible via Access Door / Hatch, Located: Garage, Located: Upstairs Bedroom
  • General : Attic InsulationFiberglass, Estimated R Value: R25-R30 in Main Attic
  • General : Attic VentilationRidge Vent(s)
  • General : Attic FlooringLimited Flooring
View Obstructed
View Obstructed
View Obstructed

Garage

Exterior: Garage

LIMITATION 3.1
View Obstructed

Monitor: Stored items and/or vehicle(s) prevent full inspection of the floor and walls. Thoroughly inspect the area after items are removed.

Repair Weatherstripping
Repair Weatherstripping
Repair Weatherstripping

Garage

Exterior: Garage

DEFICIENCY 3.2
Repair Weatherstripping

Repair: The garage door weatherstripping as noted is damaged and should be repaired to limit moisture and rodent intrusion into the garage.

Garage

Exterior: Garage

DEFICIENCY 3.3
Impact Reverse Adjustment Needed

Repair, Safety Issue: The garage door opener did not automatically reverse using standard testing procedures as required by the National Safety Council (door must reverse upon hitting a 2x4 block of wood laid flat on the floor below the door). There is a risk of injury, particularly to children and pets, and damage to vehicles under this condition. The opener and door should be serviced and adjusted as needed by a qualified garage door service company.

Garage

Exterior: Garage

DEFICIENCY 3.4
Routine Settlement Cracking (Garage)

Repair, Monitor: Cracks such as these fall within the range of normal settlement. Repair cosmetically and monitor for subsequent movement. Should further movement occur, consult a foundation contractor.

Garage Info

  • General : Garage TypeAttached
  • General : Number Of BaysTwo Car
  • General : Overhead Garage DoorsWood, Automatic Opener (electric eye reversing mechanism)
Water Staining At Foundation
Water Staining At Foundation
Water Staining At Foundation

Structural Components

Structural: Crawlspace

DEFICIENCY 4.1
Water Staining At Foundation

Repair, Monitor: Evidence of previous or active moisture penetration was observed in the crawlspace, especially as noted. Wet basements and crawlspaces risk building damage from rot and insects and can cause interior microbial growth or mildew (a microbial growth assessment is not included in this inspection). Roof and lot drainage repairs or improvements should be addressed as a first step to controlling water intrusion into the crawlspace (see Exterior and/or Roofing Sections). This condition should then be monitored.

Efflorescence Noted At Foundation
Efflorescence Noted At Foundation

Structural Components

Structural: Foundation

DEFICIENCY 4.2
Efflorescence Noted At Foundation

Water pressure from the far side of the foundation is penetrating the wall and leaching salts from the masonry and mortar. The salts themselves are harmless but indicative of persistent moisture. Consult with a licensed water-proofing contractor for remediation as needed.

Structural Components

Structural: Floor Structure

DEFICIENCY 4.3
Floor Joist Overly Notched / Cracked

Repair: A floor joist was cracked / overly notched as noted. This weakens the joist and can cause floor settlement in the future.

Water Damage / Rot Noted - Repair
Water Damage / Rot Noted - Repair
Water Damage / Rot Noted - Repair

Structural Components

Structural: Floor Structure

DEFICIENCY 4.4
Water Damage / Rot Noted - Repair

Repair: The floor structure as noted shows evidence of advanced water damage and rotting. Rot weakens the structure and can cause building settlement. Damaged wood should be repaired or replaced and the conditions that have promoted the rot should be corrected. Consult a qualified framing contractor for further evaluation and options for repair, as well as prevention of future damage.

Structural Components Info

  • General : FoundationCrawlspace Configuration, Slab on Grade (Garage Only), Concrete Block Walls
  • General : Columns/PiersSteel Columns, Concrete Block Piers
  • General : Floor StructureWood Joists - 2x10, Plywood Floor Decking
  • General : Wall StructureWood Frame, Stud Size: 2x4, Above Components Assumed (not totally visible)
  • General : Ceiling StructureWood Joist - 2x8, Wood Joist - 2x10, Not Totally Visible
  • General : Roof StructureWood Rafters - 2x6, Plywood Sheathing
  • General : Crawlspace AccessAccessible via Exterior Access Door / Hatch

Roofing System

General

LIMITATION 5.1
Roof Height / Slope Notice

Due to the steep slope and/or height of the roof structure, the roof could not be safely walked and was viewed from the ground only using binoculars or from a ladder at the eaves. Some sections of the roof could not be viewed.

Roofing System

Roofing: Shingles / Membrane

DEFICIENCY 5.2
Displaced Shingles Noted

Repair: Some shingles were observed lifting, displaced, or otherwise damaged. Damaged and displaced shingles can contribute to roof leakage. Have a qualified roofer provide further evaluation and replace all missing or defective components, ensuring proper operation of the roofing systems.

Roofing System

Roofing: Flashings

DEFICIENCY 5.3
Skylight - Monitor

Monitor: The flashing components at the skylights should be carefully monitored, as these areas are extremely vulnerable to leakage.

Roofing System

Roofing: Gutters / Downspouts

DEFICIENCY 5.4
Underground Piping Disconnect From Downspout

Repair: Downspout connections to underground piping need to be secured as noted. The piping should be screwed to the downspout and sealed to prevent moisture leakage next to the foundation, a potential source of leaks into the interior. Make sure all piping is clear and free flowing. Ribbed (black corrugated) piping is more prone to become blocked with debris than smooth wall piping.

Roofing System Info

  • General : Roof TypeComposition Shingle Architectural Style
  • General : Roof FlashingsMetal, Drip Edge Flashing
  • General : ChimneysMetal Flue / Stucco Veneer, Rain Pan and Vermin Screen
  • General : Gutters And DownspoutsAluminum
  • General : SkylightsPlastic Bubble Type

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.1
Previous Stucco Repairs Noted

Monitor: Previous repairs to the exterior EIFS veneer were noted, which align with interior drywall repairs and water damage in the crawlspace (see the Interior and Structural sections). Consult the seller for details on all repairs, as well as any documentation, warranties, etc., provided by the contractor who performed the work.

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.2
EIFS Warning

Monitor, Possible Concern: EIFS (Exterior Insulation and Finish System - sometimes referred to as "Synthetic Stucco"), as noted on this structure, has had moisture problems in the past with poor installations. It is important that these systems are kept well caulked and sealed to prevent moisture from infiltrating the structure, which can cause damage. All windows, doors, chimneys and intersecting roofs should be properly flashed. Consider having the entire veneer inspected by a stucco repair contractor for repairs and improvements that may be needed.

Exterior Components

Exterior Veneer: Stucco

DEFICIENCY 6.3
EIFS Grade Contact

Repair: Synthetic stucco as noted is a weather sensitive material that should be kept well protected and sealed at all times. The bottom edge of this veneer appears to be in contact with the soil, which can be a source of moisture and insect infiltration. All foam board should be cut back to provide at least 6" clearance with the soil and the exposed edges properly sealed. All joints with woodwork should be properly caulked. All windows, doors, chimneys and intersecting roofs should be properly flashed. Consult with a professional stucco contractor adept in repairing these systems.

Adjust Exterior Door
Adjust Exterior Door
Adjust Exterior Door

Exterior Components

Exterior: Windows / Doors

DEFICIENCY 6.4
Adjust Exterior Door

Improve: Exterior doors should be adjusted to close and fit properly as noted for ease of operation and to limit outside air and moisture infiltration.

Exterior Components

Exterior: Windows / Doors

DEFICIENCY 6.5
Service Door Locks

Improve: Exterior door locks that are difficult to operate as noted should be oiled and serviced for proper locking of the doors. Consider changing the locks altogether for proper operation and to reduce future maintenance.

Exterior Components

Exterior: Decks

DEFICIENCY 6.6
Bolts At Ledger Band Inadequate

Repair, Safety Issue: The bolts attaching the deck ledger to the structure of the house appear to be inadequate. Consult a deck contractor for further evaluation and installation of properly sized and spaced bolts as needed to prevent the deck from pulling away from the structure.

Exterior Components

Exterior: Decks

DEFICIENCY 6.7
Deck Railing Picket Spacings

Repair, Safety Issue: The openings between pickets of the deck railing is more than allowed by present day safety standards for child safety (max. 4" spacings recommended). Recommend covering these with mesh or a plastic shield or otherwise, the pickets should be altered as needed.

Exterior Components

Exterior: Decks

DEFICIENCY 6.8
Handrail Graspability

Repair, Safety Issue: The handrails as noted do not meet current safety standards for proper grasping of the top of the rail. The hand grip portion of the rail should have a minimum width of 1 1/4" and a maximum width of 2 5/8", which should be improved as needed for proper grasping of the rails.

Exterior Components

Exterior: Decks

DEFICIENCY 6.9
Landing Needed At Deck Stairs

Improve, Safety Issue: Deck stairs should terminate at a concrete landing to prevent tripping or falling. Consult a deck contractor or qualified handy person for installation of a landing.

Exterior Components

Exterior: Decks

DEFICIENCY 6.10
Deck 2x2" Ledger Warning

Improve: Until recently, a 2x2" wood ledger was deemed suitable as long as it was fastened below each joist with a minimum of three 16d nails. Recent changes in deck codes no longer recognize this as an adequate or safe connection. Consider evaluation by decking contractor for upgrades to the deck that may improve its longevity and safety. In many cases, the addition of simple hardware (such as joist hangers) can be done relatively easily and without great cost.

Patio Settled / Cracked
Patio Settled / Cracked
Patio Settled / Cracked

Exterior Components

Exterior: Patios / Stoops / Steps

DEFICIENCY 6.11
Patio Settled / Cracked

Monitor, Possible Repair: The patio has settled and cracked and may need repair or replacement in the future.

Driveway Settlement / Heaving
Driveway Settlement / Heaving
Driveway Settlement / Heaving

Exterior Components

Exterior: Driveway / Sidewalks

DEFICIENCY 6.12
Driveway Settlement / Heaving

Monitor, Future Repair: The driveway has heaved and cracked in some areas as noted and will need repair or replacement in the future.

Walkway Trip Hazard
Walkway Trip Hazard
Walkway Trip Hazard

Exterior Components

Exterior: Driveway / Sidewalks

DEFICIENCY 6.13
Walkway Trip Hazard

Improve, Safety Issue: The walkway as noted presents a trip hazard and should be altered as needed for improved safety.

Exterior Components

Exterior: Retaining Walls

DEFICIENCY 6.14
Guardrail Needed At Retaining Wall

Repair, Safety Issue: Current safety standards require a guardrail for walking areas that are more than 30" off the ground. This provision also applies to finish grades above retaining walls that are attached to the structure. There was no guardrail at the retaining wall as noted and should be installed as needed.

Exterior Components

Exterior: Lot / Drainage

DEFICIENCY 6.15
Soil Erosion Noted

Monitor, Possible Repair: Signs of soil erosion and wash were noted. If this condition persists, drainage improvements or grade stabilization measures may be necessary to prevent further erosion of the ground.

Exterior Components

Exterior: Landscaping / Fencing

DEFICIENCY 6.16
Cut Back Shrubbery / Vegetation

Improve: The shrubbery and vegetation growing near exterior walls as noted should be kept trimmed away from siding, window trims, and the eaves to reduce risk of insect and water damage. Overhanging tree branches should be cut back to prevent future damage to the roofing and gutters and to prevent rodent infestations into the attic.

Exterior Components

Exterior: Landscaping / Fencing

DEFICIENCY 6.17
Adjust Gate / Latch

Improve: The gate and/or latch mechanism needs adjustment to function properly.

Fence Damaged
Fence Damaged
Fence Damaged

Exterior Components

Exterior: Landscaping / Fencing

DEFICIENCY 6.18
Fence Damaged

Repair: Consult a fence contractor or qualified handy person for repairs.

Exterior Components Info

  • General : Wall CoveringEIFS (Exterior Insulation and Finishing System - "Synthetic Stucco")
  • General : Eaves / Soffits / FasciasWood
  • General : Exterior DoorsWood, Metal
  • General : Window / Door Frames And TrimWood
  • General : Entry Driveways / Walkways / PatiosExposed Aggregate Concrete
  • General : Front Entry / PorchTile
  • General : Other Porches / Decks / Steps And RailingsPainted Wood Deck, Stone
  • General : Surface DrainageLevel Grade
  • General : Retaining WallsDecorative Block
  • General : FencingWood, Chain Link
  • General : Number Of Exterior Doors6
To view additional Exterior Components Photos, Click Here.

Electrical System

Electrical: Panels

DEFICIENCY 7.1
Label Panel

Improve: The circuits in the electrical panel box should be labeled for proper identification of the equipment served by the breakers.

Electrical System

Electrical: Panels

DEFICIENCY 7.2
Panel Is Crowded

Improve: The main distribution panel is crowded with breakers. A larger panel, or an auxiliary panel, would be desirable, especially if electrical additions are planned.

Electrical System

Electrical: Panels

DEFICIENCY 7.3
Grounds & Neutrals Double Tapped (Improve)

Repair, Improve: Previous safety standards permitted grounds and neutrals to share the same spot on a buss bar, but modern standards require them to be separated. Consider consulting an electrician for evaluation and repair.

Electrical System

Electrical: Panels

DEFICIENCY 7.4
Advanced Age Of Panel

Improve: The electrical panel appears to be an older model that may be reaching the end of its servicable lifespan (approximately 40 years for a typical breaker panel). Consult an electrician for further evaluation and possible replacement.

Loose Outlet
Loose Outlet
Loose Outlet

Electrical System

Electrical: Outlets

DEFICIENCY 7.5
Loose Outlet

Repair: Loose outlet(s) as noted should be tightened to prevent the loosening of the wiring connections in the future.

Electrical System

Electrical: Outlets

DEFICIENCY 7.6
4 Prong Outlet Needed At Dryer (Improve)

Improve: A three-prong outlet was noted at the laundry, but newer dryers utilize a four-prong plug (although many do support replacing the cord with a three-prong version). Consult an electrician for replacement as necessary.

Electrical System

Electrical: Outlets

DEFICIENCY 7.8
GFCI Needed At Whirlpool Bath

Possible Repair, Safety Issue: A ground fault circuit interrupter (GFCI) should be installed on the circuit for the whirlpool bathtub. The presence of this component could not be confirmed due to a lack of access under the tub (see "Plumbing" Section), and no labeled GFCI circuit breaker was noted in the main panel. A ground fault circuit interrupter offers protection from shock or electrocution.

Cover Missing At Floor Outlet
Cover Missing At Floor Outlet

Electrical System

Electrical: Outlets

DEFICIENCY 7.9
Cover Missing At Floor Outlet

Repair, Safety Issue: Floor outlets are required to be sealed when not in use. Consult a handy person person or electrician for installation of appropriate covers at all floor outlets.

Panel Photos
Panel Photos
Panel Photos

ADDITIONAL INFO - CUSTOM 7.10

Panel Photos

Reference photos of service panel(s). Any infrared images included are for your reference only and do not indicate overheating wiring or components at the time of inspection, unless specifically mentioned above.

Electrical System Info

  • General : Size Of Electrical Service / Main Disconnect120/240 Volt Main Service - Service Size: 200 Amps
  • General : Service DropUnderground
  • General : Electrical Service ConductorsAluminum - 4/0 AWG
  • General : Main Service Disconnect LocationMain Panel
  • General : Service GroundingCopper Ground Wire, Ground Connection Not Visible
  • General : Distribution Panel Location(s)Garage
  • General : Distribution Sub-Panel(s)None
  • General : Distribution Panel Manufacturer(s)Square D
  • General : Distribution Wiring"Romex"
  • General : Switches And ReceptaclesGrounded
  • General : Ground Fault Circuit Interrupters (GFCI)Exterior, Bathrooms, Kitchen (Partial)
  • General : Arc Fault Circuit Interrupters (AFCI)None Found
  • General : Smoke DetectorsPresent, Upgrades Or Installation Needed
  • General : Security SystemYes
To view additional Electrical System Photos, Click Here.
A/C Units Built Prior To 2010 Will Need Replacement
A/C Units Built Prior To 2010 Will Need Replacement
A/C Units Built Prior To 2010 Will Need Replacement

Cooling System

Cooling: Central Air System

DEFICIENCY 8.1
A/C Units Built Prior To 2010 Will Need Replacement

Monitor, Future Repair:  The outdoor condensing unit(s) at the location pictured appear to have been manufactured before 2010 and more than likely used an older R-22 refrigerant (typically known as "Freon").  This refrigerant is no longer allowed in equipment manufactured after 2010 due to environmental concerns and was replaced by R-410A refrigerant.  While still technically available, Freon is now harder to come by and prohibitvely expensive.

Cooling System

Cooling: Outdoor Condensing Unit

DEFICIENCY 8.2
Improve Condensate Drain

Improve: The discharge location of the condensate line as noted should be improved so that it discharges at least 10 feet from the foundations to prevent unnecessary moisture near the structure.

Cooling System

Cooling: Outdoor Condensing Unit

DEFICIENCY 8.3
Insulation Damage At Exterior Refrigerant Lines

Improve: Damaged and missing insulation on exterior refrigerant lines as noted should be repaired or replaced for proper efficiency and protection of the copper piping.

Data Tag (Condensing Unit)
Data Tag (Condensing Unit)

ADDITIONAL INFO - CUSTOM 8.4

Data Tag (Condensing Unit)

Reference photo(s) of manufacturer data tag(s).

Cooling System Info

  • General : Cooling Equipment Energy SourceElectricity
  • General : Cooling System TypeAir Cooled Central Air
  • General : Number Of A/C SystemsTwo
  • General : Central Air ManufacturerCARRIER
  • General : Distribution MethodsDuctwork
  • General : Outdoor Unit Location(s)Rear Yard
  • General : Tonnage Capacity (1 ton serves ~600-650 sqft)8 Tons Total
  • General : Cooling Equipment Age (Typical Service Lifespan 15-20 Years)19 (x2)

Heating System

Heating: Furnace / Air Handler

LIMITATION 9.1
Too Warm To Test Furnace

When the temperature is such that the air conditioning has been consistently operating, the inspector may not turn the furnace/heat pump on in order to prevent damage to the system. Consult an HVAC contractor to perform diagnostic testing to ensure proper heating functionality.

Heating System

Heating: Combustion / Exhaust

DEFICIENCY 9.2
Flue Clearance

Repair, Safety Issue: There is insufficient clearance between the exhaust flue and combustible materials as noted (a minimum of 1" clearance is typically required). This is a fire hazard and should be corrected immediately by a qualified heating technician. Typically a metal collar is installed on the vent to prevent further movement and contact with adjoining materials.

Data Tag (Furnace/Heat Pump)
Data Tag (Furnace/Heat Pump)

ADDITIONAL INFO - CUSTOM 9.3

Data Tag (Furnace/Heat Pump)

Reference photo(s) of manufacturer data tag(s).

Heating System Info

  • General : Equipment Energy SourceNatural Gas
  • General : Heating System TypeForced Air Gas Furnace(s), Electronic Ignition
  • General : BTU Input Per Gas Furnace66000, 110000
  • General : System BrandCARRIER
  • General : Vents/Flues/ChimneysMetal Multi Wall
  • General : Distribution MethodsDuctwork
  • General : Number Of SystemsTwo
  • General : Air Filter LocationBeside Air Handler
  • General : Furnace/Heat Pump Age (Typical Service Lifespan 18-20 Years)19 (x2)
Sink Cabinet Access Limited Or Obstructed
Sink Cabinet Access Limited Or Obstructed
Sink Cabinet Access Limited Or Obstructed
Sink Cabinet Access Limited Or Obstructed

Plumbing System

Plumbing: Sinks & Faucets

LIMITATION 10.1
Sink Cabinet Access Limited Or Obstructed

Monitor: Due to storage and/or household items, access was limited or obstructed in the location(s) noted. Inspectors do not touch or move items and your inspector is not able to inspect areas where access is severely limited or obstructed. Remove obstructions and inspect the area(s) noted for signs of leakage.

Plumbing System

Plumbing: Gas Supply

DEFICIENCY 10.2
Rust At Gas Piping

Repair: Rust can lead to deterioration and possibly leakage of the gas piping. Sand and paint with Rustoleum or equivalent for minor rust conditions. Have a plumber replace if more advanced rust piping conditions are evident.

Plumbing System

Plumbing: Supply Piping

DEFICIENCY 10.3
Label Main Shutoff Valve

Improve: The main whole house water shutoff valve appears to be at the location pictured (confirm with seller) and should be labeled for proper identification. The shut-offs for the outside hose faucets should also be properly labeled for future access.  We recommend shutting off the water when leaving the house for extended periods of time.

Plumbing System

Plumbing: Supply Piping

DEFICIENCY 10.4
Install Timer For Circulating Pump

Improve: Consider installing a timer on the hot water circulating pump to prevent heat loss in the walls when not in use (e.g. at night).

Plumbing System

Plumbing: Drain / Waste / Vent (DWV) Piping

DEFICIENCY 10.5
Septic System Noted

Monitor, Possible Repair: Based on the amount of usage, septic tanks typically need servicing and cleaning every 3-5 years for proper operation and function. Consult with the seller concerning the last service date and have this performed as needed. Also, check with the seller concerning the location of the storage tank and drain fields for future servicing. The typical life of the drain fields is 30-40 years. Since the inspection of the septic system is not within the scope of this inspection, we recommend having this inspected by a licensed septic contractor. The use of a garbage disposal is typically not recommended with a septic tank system, although disposals rated as septic system safe are available.

Plumbing System

Plumbing: Toilets

DEFICIENCY 10.6
Toilet Loose

Repair: The toilet at the location noted was loose and needs repair. Have the wax ring checked for leaks and the toilet properly bolted to the floor.

Plumbing System

Plumbing: Sinks & Faucets

DEFICIENCY 10.7
Sink Stopper Repair

Repair:  The sink stopper(s) as noted did not function properly or are missing and need repair or replacement altogether.

Sink Drains Slowly
Sink Drains Slowly

Plumbing System

Plumbing: Sinks & Faucets

DEFICIENCY 10.8
Sink Drains Slowly

Repair: The sink was draining slowly indicating that an obstruction may exist or the sink stopper needs adjustment. Have the stopper adjusted and then check the P-trap and drain line for blockages and clear as needed.

Shower Diverter Needs Repair
Shower Diverter Needs Repair

Plumbing System

Plumbing: Tubs & Showers

DEFICIENCY 10.9
Shower Diverter Needs Repair

Repair: The shower diverter at the bathtub does not completely divert all of the water to the shower head, which should be improved as needed for proper function.

Plumbing System

Plumbing: Tubs & Showers

DEFICIENCY 10.10
No Whirlpool Motor Access Found

Monitor, Possible Repair: Access to the whirlpool motor should be provided (or its whereabouts should be verified with the current owner).

Plumbing System

Plumbing: Exterior Hose Faucets

DEFICIENCY 10.11
Exterior Hose Faucet Leaks

Repair: The exterior hose bibb at the location pictured does not shut off entirely or otherwise leaks at the handle, which places unnecessary moisture next to the foundation. It should be repaired or replaced as needed.

Plumbing System

Plumbing: Water Heaters

DEFICIENCY 10.12
TPR Piping Needs Bleeder Valve

Repair, Safety Issue: Current safety standards in the state of GA allow discharge piping for the TPR (Temperature and Pressure Relief) valve to route upwards, but a drain mechanism or bleeder valve is required at the lowest point of the line before it turns up. This device should be added as needed to drain water build up in the lines, which can cause damage to the TPR valve.

ADDITIONAL INFO - CUSTOM 10.13

Water Pressure Normal

Water pressure measured between 40 and 80 PSI, considered normal. No action necessary, FYI only.

Water & Gas Shutoff Valves
Water & Gas Shutoff Valves

ADDITIONAL INFO - CUSTOM 10.14

Water & Gas Shutoff Valves

Reference photos of water and gas shutoff valve locations. No action required, FYI only.

ADDITIONAL INFO - CUSTOM 10.15

Sewer Cleanout Location

Monitor: As the name implies, the sewer cleanout is used as an access point to clear clogged waste lines and for videoscope evaluation of the lines and connection to the main sewer or septic system. No action required, FYI only.

ADDITIONAL INFO - CUSTOM 10.16

Data Tag (Water Heater)

Reference photo(s) of manufacturer data tag(s).

ADDITIONAL INFO - CUSTOM 10.17

Water Temperature Normal

Monitor: Water temperature measured at or below 120 degrees Fahrenheit, the threshold for scald hazards. No action necessary, FYI only.

Plumbing System Info

  • General : Water Supply SourcePublic Water Supply
  • General : Service Pipe To House (Where Visible)Copper
  • General : Main Water Valve LocationRight Foundation Wall, Crawlspace
  • General : Interior Supply Piping (Where Visible)Copper, Pressure Regulating Valve (PRV): Located At Main Water Shutoff
  • General : Water Pressure45 psi (40-80 psi is normal)
  • General : Waste SystemPrivate Sewer System Reported by Seller
  • General : Drain/Waste/Vent Piping (Where Visible)ABS
  • General : Cleanout LocationCrawlspace
  • General : Water HeaterGas Tank(s), Expansion Tank(s)
  • General : Water Heater Age (Typical Life 8-12 Years)4
  • General : Water Heater Capacity50 Gallons
  • General : Water Heater ManufacturerA.O. SMITH
  • General : Water Heater LocationCrawlspace
  • General : Main Fuel Shut-Off Valve LocationLocated At Gas Meter (located: Right Side Yard)
To view additional Plumbing System Photos, Click Here.
Improve Ventilation In Crawlspace (Monitor)
Improve Ventilation In Crawlspace (Monitor)

Insulation / Ventilation

Insulation / Ventilation: Crawlspace

DEFICIENCY 11.1
Improve Ventilation In Crawlspace (Monitor)

Monitor: Ventilation of the crawl space may be insufficient. A full vapor barrier and dehumidifer were noted, so monitor for excess humidity and moisture in the crawlspace; if necessary, additional ventilation will help control humidity and reduce the potential for rotting of wood components, termite infestations, and toxic mildew growth. Ventilation can be improved by adding vents to the building exterior. All existing vents should be opened and cleared. If this does not prove sufficient, consult a foundation specialist.

Insulation / Ventilation

Insulation / Ventilation: Crawlspace

DEFICIENCY 11.2
Insulation Barrier Facing Wrong Way

Repair, Safety Issue: The insulation batts are installed with the paper vapor barrier exposed, which presents a fire hazard (see label on facing). The insulation should be either turned around so that the vapor barrier is not exposed or covered with an approved product (e.g., drywall). Otherwise, the insulation should be replaced with a product that does not have a paper backing (known as "unfaced" insulation).

Dehumidifier Inoperative
Dehumidifier Inoperative
Dehumidifier Inoperative
Dehumidifier Inoperative

Insulation / Ventilation

Insulation / Ventilation: Crawlspace

DEFICIENCY 11.3
Dehumidifier Inoperative

Repair: The permanent dehumidifier installed in the crawlspace was not operative at the time of inspection and had been replaced with a light duty home/office unit. Consult the owner for details, or a waterproofing contractor for further evaluation and repair as necessary.

Insulation / Ventilation Info

  • General : Exterior Wall InsulationNot Visible (R11/R13 assumed)
  • General : Basement InsulationN/A
  • General : Crawlspace InsulationNone Visible
  • General : Crawlspace VentilationExterior Wall Vents
  • General : Vapor RetardersPlastic Vapor Barrier in Crawlspace
  • General : Exhaust Fan/Vent LocationsBathroom(s), Laundry/Dryer, Cooktop Downdraft

Interior Components

Interior: Ceilings / Walls

DEFICIENCY 12.1
Repairs Noted

Monitor: Previous repairs were noted. Consult the seller for history of damage and repairs, and monitor for future leakage or damage.

Interior Components

Interior: Flooring

DEFICIENCY 12.2
Uneven Floors

Monitor: Minor unevenness was observed in the floor structure. This condition is fairly common in older structures such as this and is typically caused by the framing design, installation methods, and aging of the building. There was no evidence of need for immediate repair, however the flooring system should be monitored for further movement. The rate of movement cannot be determined in a one-time inspection.

Interior Components

Interior: Flooring

DEFICIENCY 12.3
Floor Tiles Cracked

Repair: One or more floor tiles were cracked and are need of repair or replacement. Consult a contractor or qualified handy person for repair or replacement.

Interior Components

Interior: Windows

DEFICIENCY 12.4
Fogged Glass

Repair: "Fogged" glass was noted, which should be replaced. This condition is typically caused by damaged seals around the perimeter of the insulated glass, which in turn allows condensation to develop between the panes. All damaged glass panels in this area should be replaced by a qualified glass replacement contractor. The contractor should inspect all other insulated panels in the house for additional condensation that may be occurring in the glass.

Interior Components

Interior: Environmental Issues

DEFICIENCY 12.5
Radon Note (Test In Progress)

Monitor, Safety Issue: Radon gas is a naturally occurring radioactive gas that is invisible, odorless and tasteless, and is the second leading cause of lung cancer, after smoking. The Environmental Protection Agency (EPA) states that a radon reading of more than 4.0 picoCuries per liter of air represents a health hazard and can lead to a higher incidence of cancer. The EPA recommends that all houses be tested for radon.  A radon evaluation is currently in progress and results will be provided separately. For more information, visit the EPA's radon website at https://www.epa.gov/radon/.

Thermal Imaging Performed
Thermal Imaging Performed

ADDITIONAL INFO - CUSTOM 12.6

Thermal Imaging Performed

Monitor: Thermal imaging was performed on the walls and ceilings of the living space. No concerns with water intrusion were noted at the time of inspection, but there were some typical, minor, warm spots where insulation may be missing, compressed, or damaged. Monitor for general comfort and consult an insulation contractor for repair if desired.

Interior Components Info

  • General : Wall And Ceiling MaterialsSheetrock
  • General : Floor SurfacesCarpet, Wood, Laminate
  • General : Shower And Tub SurroundsTile
  • General : Windows And GlazingDouble Hung, Casement, Double Pane
  • General : DoorsWood, Hollow Core

Appliances / Fireplaces

Fireplaces

DEFICIENCY 13.1
Fireplace Cleaning (With Gas Logs)

Repair, Safety Issue: The fireplace chimney could use cleaning due to the presence of built-up soot in the chimney from the gas logs. All flues and gas connections should be checked on an annual basis for proper safety.

Appliances / Fireplaces

Fireplaces

DEFICIENCY 13.2
Install Damper Clamp For Gas Logs

Improve, Safety Issue: There was no clamp installed at the metal damper above the gas logs in the fireplace, which could allow the damper to be closed during the operation of the gas logs. Consider installing this safety device or otherwise insure that the damper is left open when the gas logs are turned on. Also recommend installing a carbon monoxide alarm near the fireplace.

Appliances / Fireplaces

Appliances: Cooktop / Oven

DEFICIENCY 13.3
Gas Shut-Off Valve Needed

Repair, Safety Issue: There does not appear to be a gas shut-off valve below the cooktop, which should be added as needed for proper control and safety.

Appliances / Fireplaces

Appliances: Cooktop / Oven

DEFICIENCY 13.4
Flexible Gas Piping Noted At Cooktop

Improve: Flexible gas piping can be prone to mechanical damage and leakage. Use caution when placing items below the cooktop, or make sure shelving is installed to prevent damage to the gas line. Consider having a plumber or appliance contractor add a section of rigid pipe if possible.

Appliances / Fireplaces

Appliances: Dryer / Washing Machine

DEFICIENCY 13.5
Flexible Vent Piping Noted At Dryer

Improve, Safety Issue: The flexible clothes dryer exhaust vent pipe as noted should be replaced semi-rigid, or, ideally, rigid smooth wall piping where possible to prevent lint build-up in the line which can cause damage and possible fires at the dryer element.

Appliances / Fireplaces

Appliances: Dryer / Washing Machine

DEFICIENCY 13.6
Clean Dryer Vent

Repair, Safety Issue: The clothes dryer exhaust vent pipe appears clogged with lint and should be cleaned. Blocked piping can cause damage and possible fires at the dryer element.

Appliances / Fireplaces

Appliances: Dryer / Washing Machine

DEFICIENCY 13.7
Use Stainless Steel Braided Hoses For Washing Machine

Improve, Monitor: Recommend installing stainless steel braided hoses for the water connections to the washing machine for added protection against damage to interior finishes from possible leaks at these connections.

Appliances / Fireplaces

Appliances: Other Equipment

DEFICIENCY 13.9
Outdoor Grill Igniter Inoperative

Repair: The electronic igniter for the outdoor grill did not work when tested using normal controls. Consult the seller for details of operation, or consult an appliance repair technician for troubleshooting and repair.

Appliances / Fireplaces Info

  • General : Appliances TestedElectric Range / Oven, Electric Cooktop, Built-in Microwave Oven, Dishwasher, Refrigerator (with ice-maker), Garbage Disposal
  • General : Laundry Facility240 Volt Circuit for Dryer (3 Pronged Plug), Hot and Cold Water Supply for Washer, Dryer Vented to Building Exterior
  • General : FireplacesMetal Firebox (with Masonry Insert), Metal Flue, Damper, Gas Logs
  • General : Other ComponentsDoor Bell, Cooktop Downdraft, Outdoor Cooking Equipment (permanent gas/propane connection only)

Termite, Rodent, Insect and Pest Activity Info

  • General : Wood Destroying Organism (WDO) ActivityNone noted

Post Inspection Checklist Info

  • Appliances : Ovens And RangesTurned Off
  • Appliances : DishwasherTurned Off, Drained
  • Appliances : Refrigerators And FreezersClosed, Functioning
  • Appliances : Microwave Oven (Built-In Only)Turned Off
  • Appliances : Garbage DisposalTurned Off
  • Fireplaces : Wood Burning FireplaceNone
  • Fireplaces : Gas FireplacesTurned Off
  • Thermostat (Heating/Cooling Systems) : Thermostat SettingsChanged to Pre-Inspection Settings
  • GFCIs and AFCIs : Utility Rooms, Laundry Rooms, Basement/CrawlspaceReceptacles Functioning
  • GFCIs and AFCIs : Kitchens And BarsNone
  • GFCIs and AFCIs : Garage And ExteriorReceptacles Functioning
  • GFCIs and AFCIs : BathroomsReceptacles Functioning